This 250 A, 600 V fuse has a dual-element, time-delay, current-limiting design. Specified protection functions include motor overload, ground-fault and short-circuit protection.

  • 250 A, 600 V Fuse
  • Dual-Element Time Delay
  • AC/DC Interrupt Ratings
  • Current-Limiting Protection
  • Blade-End Terminals
  • Recommended Fuse Blocks

Product Overview

This 250 A, 600 V fuse has a dual-element, time-delay, current-limiting design. Specified protection functions include motor overload, ground-fault and short-circuit protection.

Technical Specifications

Product information and specifications for the selected item.

SKU: ECSR250

Product Information

BrandCOOER BUSS
SKUECSR250
CategoryFuses, Fuse Blocks & Holders

Key Specs

Current - Maximum250 A
AC Voltage Rating600 V AC
DC Voltage Rating300 V DC
Fits Fuse Class or TypeClass RK5

Electrical Ratings

Current - Maximum250 A
AC Voltage Rating600 V AC
DC Voltage Rating300 V DC
Current-limiting characteristicCurrent limiting
Time-delay10 seconds minimum at 500% of rated current
Current-limiting protectionCurrent limitation helps protect downstream components from high fault currents
Selective coordination2:1 selective coordination amp ratio
DC interrupting rating20 kAIC at 300 Vdc
Protection functionsMotor overload, ground fault and short-circuit protection
Overload and surge applicationApplicable to circuits subject to temporary motor overloads and surge currents
Response time at 500%10 s
AC interrupting rating200 kAIC at 600 Vac
Motor fuse sizing guidanceAs close as 125% of motor FLA

Fuse Type & Indication

Fits Fuse Class or TypeClass RK5
Visual IndicationNon-Indicating
End-cap safetyReduces exposure to live parts and extends air gap between adjacent mounted fuse blades or housing
Element constructionDual-element, time-delay design with separate overload and short-circuit elements
Terminal configurationBlade end x blade end
UL standardUL 248-12
CE markCE marked
cULus listingListed, file No. JDDZ.E4273
Recommended fuse blocksRM60400-1CR, RM60400-2CR, RM60400-3CR
End-cap constructionInsulated end caps; reduces exposure to live parts and extends air gap
CE markingCE Marked
Terminal connectionBlade end x blade end
Element configurationDual element
CSA standardCSA C22.2 No. 248.12

Dimensions & Weight

Height (in.)2.34
Width (in.)2.34
Length (in.)11.63
Weight (lb.)2.45