This 30 kVA, three-phase dry-type transformer has a steel enclosure and converts 480V delta input to 120/240V wye power. It is used in commercial and industrial building power distribution.
This 30 kVA, three-phase dry-type transformer has a steel enclosure and converts 480V delta input to 120/240V wye power. It is used in commercial and industrial building power distribution.
This 30 kVA, three-phase dry-type transformer has a steel enclosure and converts 480V delta input to 120/240V wye power. It is used in commercial and industrial building power distribution.
Product information and specifications for the selected item.
| Brands we stock | Jefferson Electric |
|---|---|
| SKU | T30KVA 480V-120/240 |
| Category | Electrical Transformers |
| Rated Power (kVA) | 30 |
|---|---|
| Temperature Rise (C) | 150 |
| Winding Material | Aluminum |
| Rated Power (kVA) | 30 |
|---|---|
| Temperature Rise (C) | 150 |
| Insulation class | 220 °C |
| Center-tap single-phase load limit | Single-phase load on the 120 V center tap must not exceed 5% of the three-phase kVA rating. |
| Operating frequency | 60 Hz |
| Primary tap endpoint settings | 504 V at tap 1 to 432 V at tap 7, per coil |
| Primary tap voltage settings | 504, 492, 480, 468, 456, 444, or 432 V |
| Primary tap configuration | 2 taps at 2.5% FCAN and 4 taps at 2.5% FCBN. |
| Separate-transformer threshold | Use a separate single-phase transformer if the single-phase load exceeds 5%. |
| 120V center-tap loading limit | Single-phase load must not exceed 5% of the three-phase kVA rating; use a separate single-phase transformer above that limit. |
| Frequency | 60 standard; 50 optional Hz |
| Input-side fusing | Fuse the input side per current NEC requirements. |
| Winding Material | Aluminum |
|---|---|
| Material | Steel |
| Tap construction | Staggered front loop taps. |
| Enclosure finish | Heat-cured ASA-61 gray powder coat. |
| Finish | Heat-cured ASA-61 gray powder coat finish |
| Termination lugs | Termination lugs provided on catalog units through 75 kVA. |
| Three-phase secondary terminals | X1, X2, and X3. |
| Connection compartment | Large connection compartment for wiring and installation. |
| 120 V single-phase secondary terminals | X1–X4 or X2–X4. |
| Installation environment | Indoor and outdoor use. |
| Secondary terminal connections | 240V three-phase: X1/X2/X3; 120V single-phase: X1–X4 or X2–X4. |
| Center-tap location | The center tap is on the center coil. |
| High-leg connection | Connect X3 (the high leg) to phase B; do not use X3 for 120 V lighting. |
| Vibration isolation | Vibration-isolation pads. |
| Shield configuration | No shield (model suffix code 0) |
| Certifications and Listings | CSA Certified, cULus Listed, DOE, UL Listed |
|---|
| Height (in.) | 25 |
|---|---|
| Width (in.) | 22 |
| Length (in.) | 22 |