{"product_id":"4-x-4-x-4-pvc-junction-box","title":"4\" × 4\" × 4\" PVC Junction Box","description":"\u003cdiv style=\"max-width:1120px;margin:0 auto;color:#374151;font-family:inherit;line-height:1.6;\"\u003e\n\u003csection style=\"padding:22px 24px;border:1px solid #E5E7EB;border-top:5px solid #DC0224;border-radius:14px;background:linear-gradient(135deg,#FFFFFF 0%,#F7F7F7 100%);box-shadow:0 4px 14px rgba(17,24,39,0.07);\"\u003e\u003cp style=\"margin:0 0 8px;color:#DC0224;font-size:0.78rem;line-height:1.3;font-weight:800;letter-spacing:0.08em;text-transform:uppercase;\"\u003eExcel Lighting \u0026amp; Electrical Supply Co.\u003c\/p\u003e\n\u003ch2 style=\"margin:0 0 10px;color:#1F2937;font-size:1.35rem;line-height:1.3;font-weight:750;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:1rem;line-height:1.7;\"\u003eThis 4\" × 4\" × 4\" PVC junction box encloses electrical connections. It is used in indoor and outdoor electrical installations.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"margin:28px 0 0;\"\u003e\u003ch2 style=\"margin:0 0 14px;color:#1F2937;font-size:1.25rem;line-height:1.3;font-weight:700;\"\u003eKey Features\u003c\/h2\u003e\n\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(220px,1fr));gap:14px;\"\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003e4\" × 4\" × 4\" size\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eThe box is sized 4 in. × 4 in. × 4 in.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003ePVC material\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eThe box is made of PVC.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eNEMA 4X rating\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eThe enclosure has a NEMA 4X rating.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #E5E7EB;border-radius:12px;padding:18px;box-shadow:0 2px 8px rgba(17,24,39,0.06);\"\u003e\n\u003ch3 style=\"margin:0 0 8px;color:#1F2937;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eGray color\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;font-size:0.95rem;line-height:1.6;\"\u003eThe enclosure is gray.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection style=\"margin:28px 0 0;padding:20px;border:1px solid #E5E7EB;border-left:4px solid #DC0224;border-radius:12px;background:#F9FAFB;\"\u003e\u003ch2 style=\"margin:0 0 12px;color:#1F2937;font-size:1.2rem;line-height:1.3;font-weight:700;\"\u003ePractical Applications\u003c\/h2\u003e\n\u003cul style=\"margin:0;padding-left:20px;color:#4B5563;font-size:0.95rem;line-height:1.55;\"\u003e\n\u003cli style=\"margin:0 0 8px;padding-left:2px;\"\u003eIndoor electrical junctions\u003c\/li\u003e\n\u003cli style=\"margin:0 0 8px;padding-left:2px;\"\u003eOutdoor electrical junctions\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003c\/div\u003e\u003c!-- registry-additional-specifications:start --\u003e\u003csection style=\"margin:28px 0 0;\"\u003e\u003ch2 style=\"margin:0 0 14px;color:#1F2937;font-size:1.25rem;line-height:1.3;font-weight:700;\"\u003eAdditional specifications\u003c\/h2\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · JB-R.444 · Electrical\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eFitting bonding\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eThe box cannot maintain an electrical bond between fittings; provide proper jumpers or other bonding mechanisms per NEC.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eConductor and insulation requirement\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eCopper conductors; insulation rated 75 or higher °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eMinimum electrical clearance\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eAt least 1\/2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · JBX444 · Compliance\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eApplicable standards\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eUL 50\/50E; CSA 94.1\/94.2; CSA C22.2 No. 85; CSA C22.2 No. 40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eUL 50\/50E, CSA 94.1\/94.2, CSA C22.2 No.85, CSA C22.2 No.40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eOutdoor suitability standard\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eUL 746C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · JB-R.444 · Environmental\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eWet-location suitability\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eSuitable for wet locations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eDirect-burial suitability\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eSuitable for direct burial applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eUV resistance\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003ef1 per UL 746C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eWater immersion performance\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003ef1 per UL 746C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · JB-R.444 · Installation\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eLid closure condition\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eThe lid must close freely without wire interference and be secured with the provided mounting snaps.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eMounting-fastener torque\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e15–20 in-lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eMounting orientation\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eMount the back wall between vertical and a 2-degree pitch.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eConduit-hub installation sequence\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eConnect the hub to the conduit before connecting the hub to the enclosure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eMounting screw diameter\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e#10 minimum; 1\/4 in maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eSystem grounding requirements\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eInstaller is responsible for system grounding per NEC Sections 690.41 through 690.47.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eConductor-fitting drill zones\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eApproved conductor-fitting drill zones are on all four sides of the base; remove burrs after drilling.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eLid snap installation\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eTurn lid mounting snaps to the locked position before installation; align corners and press the lid onto the base until all snaps lock.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eWeep-hole drilling\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eFor Type 2\/3R use when required, drill two 3\/16-in-diameter holes at the enclosure's lowest point.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · JBX444 · Operating Conditions\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eRecommended operating temperature\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e-40°C to 50°C (-40°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · JBX444 · Installation\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eThreaded conduit connection\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eMyers Hub, Bullet Hub, or similar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eSidewall gridline guide\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eGridlines provide a quick reference for locating connection-hole cuts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eFastener tool\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e#2 Phillips screwdriver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eDrainage-hole instruction\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eFor Type 2 or 3R use, drill a 3\/16 in. (5 mm) drainage hole at the lowest point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eSolvent-cement conduit connection\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003ePVC Junction Box Adapter (JBA) and coupling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eMechanical conduit connection\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003ePVC male\/terminal adapter (TA) with locknut and O-ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · JBX444 · Construction\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eFastener operation\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eQuarter-turn fasteners; close by hand and require a tool to open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eCover gasket construction\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003ePermanently fixed to the cover; no separate gasket installation required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eCover surface\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eFlat, smooth, unribbed surface for mounting devices or labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eMounting feet\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eMolded feet are flush with the box back for close surface mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · JB-R.444 · Construction\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eImpact resistance\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eImpact-resistant\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · JBX444 · Fire\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eFlammability rating\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eUL 94V-0\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · JB-R.444 · Performance\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eOperating temperature range\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003e-40 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eUL 94 flame rating\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eV-0, 5VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · JBX444 · Environmental\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eChemical resistance\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eVery good resistance to dilute acids, dilute alkalis, oils and greases, and alcohols\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eOutdoor suitability listing\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eUL 746C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · JB-R.444 · Compatibility\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eApproved wire-connector compliance\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eMust conform to UL 50, UL 50E, and UL 508A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eFittings and strain reliefs\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eUse outdoor-rated, UL 514B and NEMA 3R-approved fittings and\/or strain reliefs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · JB-R.444 · Maintenance\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003ePeriodic inspection and replacement\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eReplace affected components immediately if reinspection finds loose components, loose fasteners, or corrosion between components.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · JB-R.444 · Compliance\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eUL and CSA standards\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eUL 50, UL 50E, UL 508A; CSA C22.2.94.1, C22.2.94.2, C22.2.286\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F9FAFB;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eETL listing\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eETL Listed (Intertek)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · JBX444 · Electrical\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eConductor compatibility\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eSuitable for 90°C-rated conductors\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 18px;border:1px solid #E5E7EB;border-radius:12px;overflow:hidden;background:#FFFFFF;\"\u003e\n\u003ch3 style=\"margin:0;padding:12px 14px;background:#757575;color:#FFFFFF;font-size:1rem;line-height:1.35;font-weight:700;\"\u003eAdditional specifications · JBX444 · Mechanical\u003c\/h3\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;border-spacing:0;font-family:inherit;\"\u003e\u003ctbody\u003e\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003cth scope=\"row\" style=\"width:42%;padding:12px 14px;border-top:1px solid #E5E7EB;color:#374151;text-align:left;vertical-align:top;font-size:0.92rem;line-height:1.45;font-weight:600;\"\u003eImpact test conditions\u003c\/th\u003e\n\u003ctd style=\"padding:12px 14px;border-top:1px solid #E5E7EB;color:#4B5563;vertical-align:top;font-size:0.92rem;line-height:1.45;\"\u003eImpact tested at ambient room temperature and -35°C (-31°F)\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003c!-- registry-additional-specifications:end --\u003e\n\u003cdiv data-excel-commodity-members=\"true\"\u003e\n\u003ch3\u003eEquivalent part numbers\u003c\/h3\u003e\n\u003cp\u003eJBX444, JB-R.444\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Commodity","offers":[{"title":"Default Title","offer_id":68367107194991,"sku":"PJB444","price":30.24,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0729\/8970\/4303\/files\/excel-sku-jbx444-5c2824bc.jpg?v=1794578417","url":"https:\/\/excelele.com\/products\/4-x-4-x-4-pvc-junction-box","provider":"Excel Lighting \u0026 Electrical Supply, Co.","version":"1.0","type":"link"}