Skip to content

50A 250V Class RK5 Time-Delay Fuse

0 Reviews
SKU
ECNR50

Brands we stock: Eaton

This 50 A, 250 V Class RK5 time-delay fuse opens a circuit under overcurrent and has a cylindrical melamine body with tin-plated copper ferrule ends. It is used in mains, feeder, and branch circuits serving motor, transformer, lighting, and heating loads.

  • 50 A current rating
  • 250 V AC rating
  • Melamine body
  • Ferrule end connections
  • 125 V DC rating
  • Class RK5 time-delay design

This 50 A, 250 V Class RK5 time-delay fuse opens a circuit under overcurrent and has a cylindrical melamine body with tin-plated copper ferrule ends. It is used in mains, feeder, and branch circuits serving motor, transformer, lighting, and heating loads.

Product Overview

This 50 A, 250 V Class RK5 time-delay fuse opens a circuit under overcurrent and has a cylindrical melamine body with tin-plated copper ferrule ends. It is used in mains, feeder, and branch circuits serving motor, transformer, lighting, and heating loads.

  • 50 A current rating
  • 250 V AC rating
  • Melamine body
  • Ferrule end connections
  • 125 V DC rating
  • Class RK5 time-delay design

Technical Specifications

Product information and specifications for the selected item.

SKU: ECNR50

Product Information

Brands we stockEaton
SKUECNR50
CategoryFuses, Fuse Blocks & Holders

Key Specs

Current - Maximum50 A
AC Voltage Rating250 V AC
DC Voltage Rating125 V DC
Fits Fuse Class or TypeClass RK5

Electrical Ratings

Current - Maximum50 A
AC Voltage Rating250 V AC
DC Voltage Rating125 V DC
Recommended applicationsMains, feeders, and branch circuits; motor/transformer inductive loads; lighting/heating non-inductive loads
Self-certified DC interrupting rating20,000 A DC
Response time10 sec at 500%
Motor protection functionsMotor overload, ground fault, and short-circuit protection
ApplicationFeeder/branch protection applications
AC interrupting rating200 kAIC
Supported load typesInductive loads (motors, transformers) and non-inductive loads (lighting, heating)
Inductive-load surge handlingCan be sized closer to inductive-load running amps and overrides normal equipment surges to reduce unnecessary openings
Motor backup sizing guidance125% FLA
Single-phasing protectionHelps protect motors against burnout from single-phasing in three-phase systems

Fuse Type & Indication

Fits Fuse Class or TypeClass RK5
Visual IndicationNon-Indicating
End termination styleFerrule end x ferrule end
End connectionsFerrule at both ends
Fuse body shapeCylindrical
Listings and standardsCE; cULus Listed (File JDDZ.E4273); UL 248-12; CSA C22.2 No. 248.12
UL listingListed, file E162363
CE markingCE marked
CSA agency file number700489
RoHS statusNo
Rejection featureGrooved ring provides a rejection feature
Body materialMelamine; tin-plated copper

Dimensions & Weight

Height (in.)2.88
Width (in.)2.88
Length (in.)10.38

Product Documents