600A 3-Pole 240V Heavy-Duty Fusible Safety Switch, NEMA 3R
0 Reviews
SKU
HF326NRA
Brands we stock: Siemens
This 600A, 3-pole, 240V heavy-duty fusible safety switch has a galvanized-steel NEMA 3R enclosure and provides manual circuit isolation with fused overcurrent protection. It is used to disconnect outdoor three-phase equipment and service-entrance circuits.
600A, 3-pole, 240V rating
Galvanized steel enclosure
Surface mounting
NEMA 3R enclosure
UL listing
Service-entrance suitability
This 600A, 3-pole, 240V heavy-duty fusible safety switch has a galvanized-steel NEMA 3R enclosure and provides manual circuit isolation with fused overcurrent protection. It is used to disconnect outdoor three-phase equipment and service-entrance circuits.
This 600A, 3-pole, 240V heavy-duty fusible safety switch has a galvanized-steel NEMA 3R enclosure and provides manual circuit isolation with fused overcurrent protection. It is used to disconnect outdoor three-phase equipment and service-entrance circuits.
600A, 3-pole, 240V rating
Galvanized steel enclosure
Surface mounting
NEMA 3R enclosure
UL listing
Service-entrance suitability
Technical Specifications
Product information and specifications for the selected item.
SKU: HF326NRA
Product Information
Brands we stock
Siemens
SKU
HF326NRA
Category
Disconnects & Safety Switches
Key Specs
Maximum Amperage (A)
600
Phase Type
3 Phase
Disconnect Type
Safety Switch
NEMA Enclosure Rating
NEMA 3R
Switch Ratings
Maximum Amperage (A)
600
Phase Type
3 Phase
Maximum DC voltage
250 V DC
DC fault-current limit
With DC-rated fuses, fault current must not exceed the fuse's marked DC interrupting rating and is limited to 10,000 A at 250 V DC.
Continuous-load limitation
For non-motor circuits, continuous load current must not exceed 80% of the fuse rating.
Short-circuit interrupting rating
10,000 AIC standard; up to 200,000 AIC with Class R or T fuses rated 400 A maximum.
Disconnect Configuration
Disconnect Type
Safety Switch
Fused
Fused
Switching action
Quick-make and quick-break switching action
Terminal connection
Mechanical lugs
Cover interlock
Defeatable dual cover interlock
Service-entrance neutral bonding
Bonding strap can be moved to the service-entrance position; bonding strap and enclosure bonding screws are each torqued to 35 lb-in.
Blade visibility
Window allows viewing of the visible blade
Neutral grounding provision
Extra ground lug on the neutral
Line/load lug configuration
UL-approved to grip two wires per lug; two lugs on each line and load end per pole.
Mounting method
Surface mounted
Line/load lug wire range
(2) 1/0 AWG–750 kcmil AWG/kcmil
Conductor material and temperature rating
75°C copper or aluminum wire
Terminal and ground-lug torque
275 lb-in wire-tightening torque for line, load, and main neutral; 80 lb-in ground-lug mounting torque.
Line/load wire range with NEC bending space
(1) 1/0 AWG–600 kcmil or (2) 1/0 AWG–500 kcmil AWG/kcmil
Fuse clip construction
Spring-loaded heat-sink fuse clip
Enclosure & Certifications
NEMA Enclosure Rating
NEMA 3R
Certifications and Listings
UL Listed
Conduit knockout sizes
Tangential knockouts for 2.00, 2.50, 3.00, and 3.50 in conduit.
Enclosure material
Galvanized steel
Service-entrance suitability
Suitable for use as service entrance equipment.
Internal touch-safe shields
Internal shields meet 2020 NEC 230.62 touch-safe requirements for service entrance equipment.