This 60A, 2-pole, 600V non-fused safety switch has a steel housing and disconnects power to a circuit. It is used indoors for electrical equipment and load disconnects.
60 A, 2-pole, 600 V rating
Steel housing
Surface mounting
NEMA 1 enclosure
UL listing
No neutral bar
This 60A, 2-pole, 600V non-fused safety switch has a steel housing and disconnects power to a circuit. It is used indoors for electrical equipment and load disconnects.
This 60A, 2-pole, 600V non-fused safety switch has a steel housing and disconnects power to a circuit. It is used indoors for electrical equipment and load disconnects.
60 A, 2-pole, 600 V rating
Steel housing
Surface mounting
NEMA 1 enclosure
UL listing
No neutral bar
Technical Specifications
Product information and specifications for the selected item.
SKU: HNF262A
Product Information
Brands we stock
Siemens
SKU
HNF262A
Category
Disconnects & Safety Switches
Key Specs
Maximum Amperage (A)
60
Maximum Wattage (W)
0
Phase Type
1 Phase
Disconnect Type
Safety Switch
NEMA Enclosure Rating
NEMA 1
Switch Ratings
Maximum Amperage (A)
60
Maximum Wattage (W)
0
Phase Type
1 Phase
Mechanical service life
10,000 typical operating cycles
Short-circuit current rating
10,000 AIC standard; 200,000 AIC when protected by Class R/J fuses
I²t rating
200,000 A²·s
Single-phase AC horsepower ratings
20 at 480 V; 25 at 600 V HP
Design E motor compatibility
Horsepower ratings also apply to Design E motors with no derating
Motor horsepower at 600 V DC
30 HP
Motor horsepower at 250 V DC
10 HP
600 V DC short-circuit rating
10,000 AIC with Class R or J fuses
Rated supply frequency
50/60 Hz
Overload current rating
12Ă— overload-current rating
Disconnect Configuration
Disconnect Type
Safety Switch
Fused
Non-Fused
Switching action
Quick-make and break switching action
Lug design
Front-removable; convertible to copper-body or compression-type lugs
Wiring space
Meets NEC wire-bending space requirements
Electrical connection
Mechanical lugs
Mounting method
Surface mounting
Conductor compatibility
Copper or aluminum conductors rated 60/75 °C
Line/load conductor range
#12-2 AWG aluminum or #14-2 AWG copper
Service entrance suitability
Suitable for use as a disconnecting means for service entrance and loads
Cover interlock
Defeatable dual cover interlock
Mechanical lug wire range
Aluminum: #12–2 AWG; copper: #14–2 AWG
Contact design
Double-break visible blade design
Enclosure & Certifications
NEMA Enclosure Rating
NEMA 1
Certifications and Listings
UL Listed
Housing material
Steel
Line-side barrier protection
Internal shields meet NEC 2020 230.62 line-side barrier requirements