60A 3-Pole 240V Heavy-Duty Fusible Safety Switch, NEMA 1
0 Reviews
SKU
HF322NA
Brands we stock: Siemens
This 60A, 3-pole, 240V heavy-duty fusible safety switch has a steel enclosure with three fuse positions and disconnects electrical loads. It is used indoors for three-phase motors, equipment, and service-entrance applications.
60A current rating
Steel enclosure
Surface mounting
3-pole, 240V configuration
NEMA 1, UL listing
Three fuse positions and solid neutral
This 60A, 3-pole, 240V heavy-duty fusible safety switch has a steel enclosure with three fuse positions and disconnects electrical loads. It is used indoors for three-phase motors, equipment, and service-entrance applications.
This 60A, 3-pole, 240V heavy-duty fusible safety switch has a steel enclosure with three fuse positions and disconnects electrical loads. It is used indoors for three-phase motors, equipment, and service-entrance applications.
60A current rating
Steel enclosure
Surface mounting
3-pole, 240V configuration
NEMA 1, UL listing
Three fuse positions and solid neutral
Technical Specifications
Product information and specifications for the selected item.
SKU: HF322NA
Product Information
Brands we stock
Siemens
SKU
HF322NA
Category
Disconnects & Safety Switches
Key Specs
Maximum Amperage (A)
60
Phase Type
3 Phase
Disconnect Type
Safety Switch
NEMA Enclosure Rating
NEMA 1
Switch Ratings
Maximum Amperage (A)
60
Phase Type
3 Phase
Horsepower ratings
240 V AC: 1-phase 3 HP standard/10 HP maximum; 3-phase 7.5 HP standard/15 HP maximum. 250 V DC: 10 HP. Standard ratings apply with non-time-delay fuses, maximum ratings with time-delay fuses; Design E motors are not derated.
I²t rating
200,000 A²·s
Supply frequency
50/60 Hz
Overload current rating
12Ă— overload-current rating, exceeding the 10Ă— industry standard.
Short-circuit withstand rating
10,000 AIC standard; up to 200,000 AIC with Class R fuse protection.
Motor-system compatibility
Suitable for grounded B-phase systems and 3-phase motor applications.
Disconnect Configuration
Disconnect Type
Safety Switch
Fused
Fused
Mounting method
Surface mounting.
Position indication
Highly visible ON/OFF indication.
Service application
Suitable as a disconnecting means for service-entrance and load applications.
Ground conductor range
#14 to #4 AWG.
Neutral configuration
Solid neutral provided.
Lug conversion
Front-removable lugs can be converted to copper-body or compression-type lugs.
Electrical connection
Mechanical lug connections.
Supported fuse classes
Class H and K fuses; Class R fuses with the required Class R fuse-clip rejecter kit.
Handle padlocking
Handle can be padlocked OFF with up to three padlocks using 5/16-in. hasps.
Actuator configuration
Single-throw actuation.
Switching mechanism
Quick-make/break switching with a double-break visible-blade design.