The ABB A26-30-01 is a three-pole contactor with one normally closed auxiliary contact. The technical specification lists a 110 VAC, 50 Hz coil and a 115–120 VAC, 60 Hz coil; ratings include 45 A AC-1 at 40 °C, 26 A AC-3 at 415 V and 55 °C, and a 690 V main-circuit rated operational voltage. ABB lists it for three-phase motor and power-circuit control, lighting, isolation, and capacitor switching.
The ABB A26-30-01 is a three-pole contactor with one normally closed auxiliary contact. The technical specification lists a 110 VAC, 50 Hz coil and a 115–120 VAC, 60 Hz coil; ratings include 45 A AC-1 at 40 °C, 26 A AC-3 at 415 V and 55 °C, and a 690 V main-circuit rated operational voltage. ABB lists it for three-phase motor and power-circuit control, lighting, isolation, and capacitor switching.
The ABB A26-30-01 is a three-pole contactor with one normally closed auxiliary contact. The technical specification lists a 110 VAC, 50 Hz coil and a 115–120 VAC, 60 Hz coil; ratings include 45 A AC-1 at 40 °C, 26 A AC-3 at 415 V and 55 °C, and a 690 V main-circuit rated operational voltage. ABB lists it for three-phase motor and power-circuit control, lighting, isolation, and capacitor switching.
Product information and specifications for the selected item.
| Brand | ABB |
|---|---|
| MPN | A26-30-01-120V |
| SKU | A26-30-01-120V |
| Category | Lighting Contactors |
| Number of Poles | 3 |
|---|---|
| Coil Voltage | 115-120 VAC (60 Hz) / 110 VAC (50 Hz) |
| Contact Type | N.C. |
| Height (in.) | 3.5433 |
| Number of Poles | 3 |
|---|---|
| Coil Voltage | 115-120 VAC (60 Hz) / 110 VAC (50 Hz) |
| Contact Type | N.C. |
| Construction | Block-type construction with an AC-operated laminated magnetic circuit |
| DIN-rail mounting | Mounting on an EN 50022 35 mm rail |
| Mechanical durability | 10 million cycles |
| CSA motor horsepower ratings | 3-phase: 7.5 hp at 200 V, 10 hp at 240 V, 20 hp at 480 V, 25 hp at 600 V; 1-phase: 2 hp at 120 V, 5 hp at 230 V |
| AC-3 rated operational current | 26 A at 220, 230, 240, 380, 400, 415 and 440 V; 22 A at 500 V; 17 A at 690 V (55 °C) |
| Auxiliary terminal degree of protection | IP20 for auxiliary terminals |
| Rated impulse withstand voltage | 8 kV |
| Auxiliary-circuit current ratings | Ith: 16 A at 40 °C; AC-15: 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/440 V, and 2 A at 500/690 V |
| Short-circuit protective fuses | 50 A gG fuse for the main circuit; 10 A gG fuse for the auxiliary circuit |
| Maximum operating altitude | 3,000 m |
| Control-circuit terminal connection | A1/A2 control terminals: M3.5; 1 N·m tightening torque; conductor ranges 2 × 1–4 mm² and 2 × 0.75–2.5 mm² |
| AC-1 rated operational current | 45 A at 40 °C; 40 A at 55 °C; 32 A at 70 °C (690 V) |
| AC-4 rated operational current | 26 A at ≤440 V; 22 A at >440 to ≤500 V; 13 A at >500 to ≤690 V |
| Maximum switching frequencies | Electrical: AC-1 600, AC-2/AC-4 300, AC-3 1,200 cycles/hour; mechanical: 3,600 cycles/hour |
| Rated insulation voltage | 1,000 V per IEC 60947-4-1/VDE 0110 Group C; 600 V per UL/CSA |
| Main terminal connection | M4 main terminals, Pozidriv No. 2; 1.7 N·m tightening torque; conductor ranges 2 × 1.5–6 mm² and 2 × 1–4 mm² |
| AC-3 rated operational power | 6.5 kW at 220/230/240 V; 11 kW at 380/400/415 V; 15 kW at 440/500/690 V |
| Operating and storage temperature | Operating: −40 to +55 °C without a thermal overload relay at 0.85–1.1 Uc; −40 to +70 °C without a relay at Uc; −25 to +55 °C with a thermal overload relay. Storage: −60 to +80 °C |
| Maximum breaking capacity | 420 A at 440 V and 170 A at 690 V (cos φ = 0.45) |
| Climatic withstand | IEC 60068-2-30 and IEC 60068-2-11; UTE C 63-100 specification II |
| AC-3 making and breaking capacity | Breaking capacity: 8 × Ie; making capacity: 10 × Ie |
| Application suitability | For 3-phase motor and power-circuit control up to 690 V AC or 220 V DC; also suitable for isolation, capacitor switching, and lighting |
| UL 508 interruption rating | 5 kA at 600 V AC with a 90 A RK5 fuse |
| Rated operational voltage, main circuit | 690 V |
| Height (in.) | 3.5433 |
|---|---|
| Width (in.) | 2.126 |
| Length (in.) | 3.685 |
| Weight (lb.) | 1.3228 |