Skip to content
ASCO

ASCO Series 300 600A J-Frame 3-Pole Automatic Transfer Switch, 120/208V 3-Phase, NEMA 3R, Non-Service-Entrance

0 Reviews
SKU
J03ATSA30600CGXF,11BE,44G

The ASCO Series 300 J-frame automatic transfer switch is rated 600 A for 120/208 V three-phase systems, with three poles, a solid neutral and open-transition operation. It is non-service-entrance rated, has a NEMA 3R enclosure, and includes the 11BE option and a thermostat-controlled 44G strip heater powered from the load terminals.

  • 600 A transfer rating
  • 120/208 V, three-phase
  • Three-pole, solid-neutral configuration
  • Automatic open-transition transfer
  • NEMA 3R enclosure
  • Thermostat-controlled 44G strip heater

Product Overview

The ASCO Series 300 J-frame automatic transfer switch is rated 600 A for 120/208 V three-phase systems, with three poles, a solid neutral and open-transition operation. It is non-service-entrance rated, has a NEMA 3R enclosure, and includes the 11BE option and a thermostat-controlled 44G strip heater powered from the load terminals.

Technical Specifications

Product information and specifications for the selected item.

SKU: J03ATSA30600CGXF,11BE,44G

Product Information

BrandASCO
MPNJ03ATSA30600CGXF,11BE,44G
SKUJ03ATSA30600CGXF,11BE,44G
CategoryAutomatic Transfer Switches

Key Specs

Maximum Amperage (A)600
Automatic/ManualAutomatic
Certifications and ListingsUL Listed

Electrical Ratings

Maximum Amperage (A)600
Neutral configurationSolid neutral terminal assembly (NTA).
Terminal wire-bending capacityUp to two 600 MCM cables per terminal
Power-connection conductor rangeTwo 2/0 AWG to 600 MCM
Wire-bending spaceSpace for up to two 600 MCM cables per terminal.
Lug screw tightening torque19 ft-lb
Ground busA 2/0-rated ground bus is provided.
Lug-screw materialAluminum alloy 6262-T9, electro-tin plated.
Ground-lug capacitySix ground-lug connections for #2–600 MCM copper cable.
Specific-breaker withstand/closing rating at 240 V maximum65 kA
Power-terminal cable capacityStandard mechanical screw-type lugs on normal, emergency, and load bus stabs; one lug per phase and neutral, each suitable for two 600 MCM Cu cables or one 4/0–600 MCM Cu/Al cable.
Terminal-lug materialAluminum alloy 6061-T6, electro-tin plated.
Minimum power-conductor temperature rating75 °C
Power-terminal typeStandard mechanical screw-type lugs on the normal, emergency, and load bus stabs

Transfer & Features

Automatic/ManualAutomatic
FeaturesMountable
Connection styleFront-connected transfer switch.
Outdoor exposure limitationNot suitable for installations exposed to wind-blown rain or snow; use Type 4 where available or provide supplemental shelter.
Transition typeOpen transition (03ATS).
Cold-weather condensation precautionsBelow 32°F, special precautions such as strip heaters are recommended to prevent condensation and freezing, especially for outdoor Type 3R enclosures.
Mounting optionsFree-standing, floor-mounted or wall-mounted.
Cable entryDesigned for top and bottom cable entry.
Standard enclosure securityNon-secure enclosures are supplied as standard for 30–600 A switch sizes.
Standard finishANSI 61 gray polyester powder finish (standard).
Enclosure construction gauge14 gauge
Open-transition transfer time<50 ms

Certifications

Certifications and ListingsUL Listed

Dimensions & Weight

Recommended front clearance24.00 in

Product Documents

  • ASCO 300 Series J-Frame Front-Connected Transfer Switches, Type 3R/12 Enclosure — Outline Drawing 1001393-002 Drawing photometric Open / download file
  • Group G Controller for ASCO Automatic & Non-Automatic Transfer Switches — User’s Guide (381333-400 H) Manual Open / download file
  • ASCO 3ATS, 3ADTS, 3NTS, 3NDTS — Installation Manual, J-Design 260–600 A / 150–600 A Transfer Switches (381333-404 B) Installation manual Open / download file
  • ASCO SERIES 300 Power Transfer Switches — Technical Data and Ordering Information Spec sheet Open / download file

Your cart

0 products 0 units

Your cart is empty.

Add products as you browse, then review them here.