586-554-2000
Mon–Fri 6:30am–5pm · Sat 8am–3pm
586-554-2000
Mon–Fri 6:30am–5pm
The Powers Fasteners 7173-25 is a steel concrete vertical hanger for 3/8-in threaded rod, supplied in a 25-pack. It measures 1.5 in overall and is specified for a 1/4-in Ă— 1.5-in Wedge-Bolt OT anchor, with a 1/4-in ANSI predrilled hole and 1-1/2-in embedment.
The Powers Fasteners 7173-25 is a steel concrete vertical hanger for 3/8-in threaded rod, supplied in a 25-pack. It measures 1.5 in overall and is specified for a 1/4-in Ă— 1.5-in Wedge-Bolt OT anchor, with a 1/4-in ANSI predrilled hole and 1-1/2-in embedment.
The Powers Fasteners 7173-25 is a steel concrete vertical hanger for 3/8-in threaded rod, supplied in a 25-pack. It measures 1.5 in overall and is specified for a 1/4-in Ă— 1.5-in Wedge-Bolt OT anchor, with a 1/4-in ANSI predrilled hole and 1-1/2-in embedment.
Product information and specifications for the selected item.
| Brand | Powers Fasteners |
|---|---|
| MPN | 7173-25 |
| SKU | 7173-25 |
| Category | Hangers & Supports |
| Pipe/Rod Size (in.) | 3/8 in |
|---|---|
| Length (in.) | 1.5 |
| Pipe/Rod Size (in.) | 3/8 in |
|---|---|
| FM approval file | J.I 3015153 |
| Load-rating basis | Reduce ultimate values by a minimum safety factor of 4.0 or greater to determine allowable working load. |
| Ultimate shear load in uncracked normal-weight concrete | 2,580 at 2,000 psi; 2,640 at 4,000 psi; 2,700 at 6,000 psi lb |
| Ultimate tension load in hollow-core concrete plank | 3,700 at center of web; 2,570 at center of core lb |
| FM-approved installation orientation | Vertical installation only |
| Metal-deck requirement | Deck must not exceed 18 gauge (0.048-in. base metal thickness) and must conform to ASTM A653. |
| Installation procedure | Install perpendicular to the base surface with a smooth, steady drive until the driver and coupling seat against it. |
| Metal-deck flute clearance | Minimum 1-1/8 in. from the lower flute edge, or use the upper flute with integral-washer clearance. |
| Finish | Zinc plating, ASTM B633, SC1, Type III (Fe/Zn5) |
| Hollow-core installation geometry | 1-1/2-in. cover above and below cores; minimum web thickness 1-1/2 in. |
| Hollow-core test condition | 8-in.-thick uncracked hollow-core concrete with minimum compressive strength of 5,000 psi. |
| Ultimate tension load in uncracked normal-weight concrete | 1,760 at 2,000 psi; 2,595 at 4,000 psi; 2,770 at 6,000 psi lb |
| FM approval status | FM Approved |
| Pre-drill depth allowance | Drill at least 1/4 in. deeper than the required embedment depth. |
| Required pre-drilling | Pre-drill with a 1/4-in. ANSI carbide bit. |
| Thread engagement | Threaded rod or bolt should fully engage the coupling thread length on vertical mount installations. |
| Lightweight-concrete test condition | Uncracked sand-lightweight concrete, f'c ≥ 3,000 psi, over a 4-1/2-in.-wide deck. |
| Seismic evaluation | Not evaluated for pipe-hanger support in earthquake zones; follow FM Global Data Sheet 1-2 restrictions. |
| Coupling material | Case hardened carbon steel |
| Ultimate load in lightweight concrete over metal deck | 1,780 tension; 1,500 at 45° lb |
| Coupling thread depth | 1/2 in. |
| Screw body material | Case hardened carbon steel |
| FM-listed maximum nominal pipe size | 4 in. |
| Thread standard | Unified Coarse Thread (UNC) |
| Length (in.) | 1.5 |
|---|
Added to cart