Eaton's TRSGF20A is an almond 20 A, 125 V tamper-resistant self-test GFCI duplex receptacle with a NEMA 5-20R configuration, back- and side-wire terminals, an indicator light, and a standard-size wallplate included.
20 A, 125 V Rating
NEMA 5-20R Duplex
Self-Test GFCI
Tamper-Resistant Outlets
Back- and Side-Wire Terminals
Standard-Size Wallplate Included
Eaton's TRSGF20A is an almond 20 A, 125 V tamper-resistant self-test GFCI duplex receptacle with a NEMA 5-20R configuration, back- and side-wire terminals, an indicator light, and a standard-size wallplate included.
Eaton's TRSGF20A is an almond 20 A, 125 V tamper-resistant self-test GFCI duplex receptacle with a NEMA 5-20R configuration, back- and side-wire terminals, an indicator light, and a standard-size wallplate included.
20 A, 125 V Rating
NEMA 5-20R Duplex
Self-Test GFCI
Tamper-Resistant Outlets
Back- and Side-Wire Terminals
Standard-Size Wallplate Included
Technical Specifications
Product information and specifications for the selected item.
SKU: TRSGF20A
Product Information
Brand
Eaton
MPN
TRSGF20A
SKU
TRSGF20A
UPC / GTIN
032664739910
Category
Receptacles & Outlets
Key Specs
Amperage (A)
20
Voltage (V)
125 V
NEMA Configuration
NEMA 5-20R
Safety Rating
GFCI, Grounded
Wire Connection Type
Screw Terminal
Electrical Ratings
Amperage (A)
20
Voltage (V)
125 V
Frequency
60 Hz
Dielectric withstand
2000 V
Overload temperature rise
Maximum 30 °C (86 °F) after 100 overload cycles at 150% of rated current (DC)
Short-circuit test result
Meets and exceeds 10 kA
Current-interrupting capability
Yes, at full-rated current
Short-circuit testing
Meets and exceeds 10 kA
Configuration & Wiring
NEMA Configuration
NEMA 5-20R
Wire Connection Type
Screw Terminal
Terminal and mounting screw head type
Tri-combo head
Allowable wire size
#14–10 AWG
Automatic grounding
Eliminates the need for a bonding jumper in a grounded metal enclosure
Terminal tightening torque
16 lbf-inch
Terminal conductor range
#14 - 10 AWG
Safety & Compatibility
Safety Rating
GFCI, Grounded
Flammability class
V2
Line/load miswiring protection
No downstream power when wired incorrectly
Listings and standards
cULus listed to UL 498 and UL 943 (file E60120); meets applicable CSA requirements; NOM certified
Temperature rating
-35 °C to 66 °C (-31 °F to 150.8 °F)
Flammability rating
UL 94 requirements met; V2 rated
GFCI trip time
0.025 seconds
Tamper-resistant code compliance
2017 and 2020 NEC Article 406.12
Features & Finish
Features
Indicator Light, Tamper Resistant
Wall Plate Included
With Wall Plate
Color Family
Almond
Material
Thermoplastic
Bundle/Single
Single Product
Terminal clamp construction
Brass-plated steel
Mounting strap construction
0.042 in thick steel, zinc-plated
Line contact construction
0.030 in thick brass
Terminal screw construction
Brass/nickel-plated steel
Dimensions & Weight
Height (in.)
4.625
Width (in.)
2
Length (in.)
2.813
Weight (lb.)
0.405
Product Documents
Installing and Testing a GFCI Receptacle (EIS-0018-E, Rev. B)
Installation manual
Open / download file