Skip to content

Eaton BR 20A Single-Pole Dual-Function AFCI/GFCI Circuit Breaker, Plug-On Neutral

0 Reviews
SKU
BRP120DF

The Eaton BRP120DF is a single-pole, 20 A, 120 V AC BR-series circuit breaker combining AFCI/GFCI functions with a plug-on-neutral connection, TEST button, and red LED trip diagnostics.

  • Dual-function AFCI/GFCI
  • 20 A, 120 V AC, single-pole
  • Eaton BR plug-on-neutral connection
  • 5 mA personnel ground-fault rating
  • #14–4 AWG branch-wire range
  • TEST button and red LED diagnostics

The Eaton BRP120DF is a single-pole, 20 A, 120 V AC BR-series circuit breaker combining AFCI/GFCI functions with a plug-on-neutral connection, TEST button, and red LED trip diagnostics.

Product Overview

The Eaton BRP120DF is a single-pole, 20 A, 120 V AC BR-series circuit breaker combining AFCI/GFCI functions with a plug-on-neutral connection, TEST button, and red LED trip diagnostics.

  • Dual-function AFCI/GFCI
  • 20 A, 120 V AC, single-pole
  • Eaton BR plug-on-neutral connection
  • 5 mA personnel ground-fault rating
  • #14–4 AWG branch-wire range
  • TEST button and red LED diagnostics

Technical Specifications

Product information and specifications for the selected item.

SKU: BRP120DF

Product Information

BrandEaton
MPNBRP120DF
SKUBRP120DF
UPC / GTIN786670009207
CategoryCircuit Breakers

Key Specs

Maximum Amperage (A)20
Voltage120 V AC
Interruption TypeAFCI/GFCI
Breaker TypeStandard
Mounting TypePlug-On
Neutral Connection TypeNeutral

Electrical Ratings

Maximum Amperage (A)20
Voltage120 V AC
Interruption TypeAFCI/GFCI
Supplemental overload detectionElectronic overload detection supplements standard mechanical bimetal protection
Personnel-protection ground-fault rating5 mA
Personnel ground-fault sensitivity5 mA
Arc-fault detection coverageDetects both low-current and high-current arc faults
Trip time at 7 mA ground faultNearly 4.5 s
Overvoltage trip threshold160 or greater V RMS
Trip time at 10 mA ground faultUp to 2.7 s

Breaker Configuration

Breaker TypeStandard
Mounting TypePlug-On
Neutral Connection TypeNeutral
Series TypeBR
Feed and wiring restrictionDo not reverse feed or backwire
Shared-neutral circuit compatibilityNot suitable for protecting shared-neutral circuits
GFCI load restrictionDo not connect electric ranges or clothes dryers whose frames are grounded by connection to the grounded conductor to the GFCI load circuit
Branch-wire terminal connectionsWhite load neutral to LOAD NEUTRAL terminal; black hot wire to LOAD terminal
Panel compatibility restrictionNot compatible with non-plug-on-neutral panels
Supported wire size range#14–4 AWG
Insulation-testing restrictionRemove the breaker before megger or high-voltage (hi-pot) testing
Branch-circuit wire size range#14–4 AWG

Pack & Smart Features

Bundle/SingleSingle Product
Pack OptionsSingle Item
Trip diagnosticsRed diagnostic LED uses repeating 1–6 blink codes to indicate the trip cause
Recommended test intervalMonthly
Self-test fail-safe responsePersistent self-test malfunction trips the breaker within 2 seconds of reset
Functional testThe TEST button checks operation of arc- and ground-fault detection
Handheld GFCI tester responseMay not trip immediately with a handheld tester; hold the tester button longer
LED diagnosticsIncluded

Dimensions & Weight

Height (in.)0.9
Width (in.)2.9
Length (in.)2.9
Weight (lb.)0.4

Product Documents

Your cart

0 products 0 units

Your cart is empty.