The Eaton Bussmann Series Fusetron FRN-R-10 is a 10 A Class RK5 dual-element time-delay fuse with current-limiting operation and ferrule-end connections. It is rated 250 VAC and 125 VDC, with interrupting ratings of 200 kA AC RMS symmetrical at 250 VAC and 20 kA DC at 125 VDC.

  • 10 A, 250 VAC / 125 VDC Ratings
  • Class RK5 Fuse
  • 200 kA AC / 20 kA DC Interrupting Rating
  • Dual-Element Time-Delay
  • Current-Limiting Operation
  • Ferrule-End Connections

The Eaton Bussmann Series Fusetron FRN-R-10 is a 10 A Class RK5 dual-element time-delay fuse with current-limiting operation and ferrule-end connections. It is rated 250 VAC and 125 VDC, with interrupting ratings of 200 kA AC RMS symmetrical at 250 VAC and 20 kA DC at 125 VDC.

Product Overview

The Eaton Bussmann Series Fusetron FRN-R-10 is a 10 A Class RK5 dual-element time-delay fuse with current-limiting operation and ferrule-end connections. It is rated 250 VAC and 125 VDC, with interrupting ratings of 200 kA AC RMS symmetrical at 250 VAC and 20 kA DC at 125 VDC.

  • 10 A, 250 VAC / 125 VDC Ratings
  • Class RK5 Fuse
  • 200 kA AC / 20 kA DC Interrupting Rating
  • Dual-Element Time-Delay
  • Current-Limiting Operation
  • Ferrule-End Connections

Technical Specifications

Product information and specifications for the selected item.

SKU: FRNR10

Product Information

BrandEaton Bussmann Series
MPNFRNR10
SKUFRNR10
CategoryFuses, Fuse Blocks & Holders

Key Specs

Current - Maximum10 A
AC Voltage Rating250 V AC
DC Voltage Rating125 V DC
Fits Fuse Class or TypeClass RK5

Electrical Ratings

Current - Maximum10 A
AC Voltage Rating250 V AC
DC Voltage Rating125 V DC
AC interrupting rating200 kAIC
Interrupting rating200 AC RMS symmetrical; 20 DC kA
DC interrupting rating20 kAIC
Selective coordination ratio2:1 amp ratio
Motor FLA sizingAs close as 125% of motor FLA

Fuse Type & Indication

Fits Fuse Class or TypeClass RK5
Visual IndicationNon-Indicating
Response time at 500%8 sec
End connectionsFerrule end X ferrule end
Fuse operating characteristicCurrent-limiting
Protection functionsMotor overload, ground fault and short-circuit protection
UL listingUL Listed to Standard 248-12
Current-limiting characteristicCurrent-limiting
Motor-load suitabilityApplicable in circuits subject to temporary motor overloads and surge currents, providing short-circuit and overload protection
Number of fuse elementsDual
CSA standardCSA C22.2 No. 248.12
CE markingCE marked
cULus listingcULus Listed; file No. JDDZ.E4273
Time-delay response8 at 500% s
ApplicationsCombination starters; motor control centers; machinery disconnects; power panelboards
CSA certificationCSA Certified to C22.2 No. 248.12