Skip to content
Eaton Bussmann

Eaton Bussmann Fusetron FRS-R Class RK5 Dual-Element Time-Delay Fuse

0 Reviews
SKU
FRS-R-5

The Eaton Bussmann Fusetron FRS-R-5 is a 5 A Class RK5 dual-element time-delay cartridge fuse rated 600 V AC and 300 V DC. It is current-limiting and non-indicating, with interrupting ratings of 200 kAIC at 600 V AC and 20 kAIC at 300 V DC.

  • Class RK5 Cartridge Fuse
  • 5 A Maximum Current
  • 600 VAC / 300 VDC Ratings
  • Interrupting Ratings
  • Dual-Element Time Delay
  • Current-Limiting Operation

The Eaton Bussmann Fusetron FRS-R-5 is a 5 A Class RK5 dual-element time-delay cartridge fuse rated 600 V AC and 300 V DC. It is current-limiting and non-indicating, with interrupting ratings of 200 kAIC at 600 V AC and 20 kAIC at 300 V DC.

Product Overview

The Eaton Bussmann Fusetron FRS-R-5 is a 5 A Class RK5 dual-element time-delay cartridge fuse rated 600 V AC and 300 V DC. It is current-limiting and non-indicating, with interrupting ratings of 200 kAIC at 600 V AC and 20 kAIC at 300 V DC.

  • Class RK5 Cartridge Fuse
  • 5 A Maximum Current
  • 600 VAC / 300 VDC Ratings
  • Interrupting Ratings
  • Dual-Element Time Delay
  • Current-Limiting Operation

Technical Specifications

Product information and specifications for the selected item.

SKU: FRS-R-5

Product Information

BrandEaton Bussmann
MPNFRS-R-5
SKUFRS-R-5
UPC / GTIN051712508223
CategoryFuses, Fuse Blocks & Holders

Key Specs

Current - Maximum5 A
AC Voltage Rating600 V AC
DC Voltage Rating300 V DC
Fits Fuse Class or TypeClass RK5

Electrical Ratings

Current - Maximum5 A
AC Voltage Rating600 V AC
DC Voltage Rating300 V DC
UL listingListed to Std 248-12; Guide JDDZ, File E4273
CE markingCE Marked
Response time at 500% rated current10 at 500% s
Motor fuse sizing guidanceSizing as close as 125% of motor FLA
CSA standardCSA C22.2 No. 248.12
CSA certificationCSA Certified, Class 1422-02, File 53787
Motor overload and surge conditionsCan be applied in circuits subject to temporary motor overloads and surge currents
Typical applicationsPower panelboards; motor control centers; combination starters; machinery disconnects
Interrupting rating200 at 600 Vac; 20 at 300 Vdc kAIC
Protection functionsMotor overload, ground fault, and short-circuit protection
Current-limiting characteristicCurrent-limiting
Selective coordination ratio2:1 amp ratio
Interrupt rating200 kAIC at 600 Vac; 20 kAIC at 300 Vdc
Fault-current limitationCurrent limitation helps protect downstream components from high fault currents
Minimum time-delay10 seconds (minimum) at 500% of rated current

Fuse Type & Indication

Fits Fuse Class or TypeClass RK5
Visual IndicationNon-Indicating
Fuse-holder compatibilityAlso fits non-rejection type fuse holders for lower-rated Class H(K) replacements
Connection styleFerrule end x ferrule end
Internal element arrangementSeparate overload and short-circuit elements
Terminal connectionFerrule end x ferrule end

Dimensions & Weight

Height (in.)0.81
Width (in.)0.81
Length (in.)5
Weight (lb.)0.14