The Eaton Bussmann LPJ-100SP is a Low-Peak Class J cartridge fuse rated 100 A at 600 VAC or 300 VDC. It has 300 kA AC and 100 kA DC interrupting ratings, a dual-element current-limiting time-delay design, and non-indicating construction.
The Eaton Bussmann LPJ-100SP is a Low-Peak Class J cartridge fuse rated 100 A at 600 VAC or 300 VDC. It has 300 kA AC and 100 kA DC interrupting ratings, a dual-element current-limiting time-delay design, and non-indicating construction.
The Eaton Bussmann LPJ-100SP is a Low-Peak Class J cartridge fuse rated 100 A at 600 VAC or 300 VDC. It has 300 kA AC and 100 kA DC interrupting ratings, a dual-element current-limiting time-delay design, and non-indicating construction.
Product information and specifications for the selected item.
| Brand | Eaton Bussmann |
|---|---|
| MPN | LPJ-100SP |
| SKU | LPJ-100SP |
| UPC / GTIN | 051712523400 |
| Category | Fuses, Fuse Blocks & Holders |
| Current - Maximum | 100 A |
|---|---|
| AC Voltage Rating | 600 V AC |
| DC Voltage Rating | 300 V DC |
| Fits Fuse Class or Type | Class J |
| Current - Maximum | 100 A |
|---|---|
| AC Voltage Rating | 600 V AC |
| DC Voltage Rating | 300 V DC |
| UL/cULus listing | cULus Listed, file No. JDDZ.E4273 |
| Agency approvals | cULus listed (file JDDZ.E4273; UL 248-8); CSA C22.2 No. 248.8; CE |
| DC interrupting rating | 100 kA |
| RoHS status | Compliant |
| Interrupting rating | 300 (AC RMS symmetrical); 100 (DC) kA |
| Selective coordination ratio | 2:1 ampacity ratio within the Low-Peak fuse family |
| Motor-controller coordination | When properly sized, can provide Type 2 no-damage coordinated protection for NEMA and IEC motor controllers |
| RoHS compliance | RoHS Compliant |
| CE mark | CE |
| CSA product standard | CSA C22.2 No. 248.8 |
| AC interrupting rating | 300 kA |
| Let-through current at 100 kA prospective short-circuit current | 5 (apparent RMS symmetrical) kA |
| Fits Fuse Class or Type | Class J |
|---|---|
| Visual Indication | Non-Indicating |
| Fuse element design | Dual-element, current-limiting |
| Time-delay performance | 10 seconds minimum at 500% of rated current |
| Minimum time-delay response | 10 (minimum) at 500% of rated current seconds |
| Current-limiting characteristic | Current-limiting |
| Typical applications | Power panelboards; branch circuit breaker panelboard mains; machinery disconnects; industrial control |
| Height (in.) | 4.625 |
|---|---|
| Width (in.) | 1.156 |
| Length (in.) | 1.156 |
| Weight (lb.) | 0.3 |