Skip to content

Eaton CH270 70A 2-Pole Standard Circuit Breaker

0 Reviews
SKU
CH270

The Eaton CH270 is a 70 A, two-pole standard-trip circuit breaker rated 120/240 V AC, with a 10 kAIC interrupt rating and common-trip operation. It uses plug-on mounting for Type CH loadcenters and is UL Listed and CSA Certified.

  • 70 A, Two-Pole Common Trip
  • 120/240 V AC Rating
  • 10 kAIC Interrupt Rating
  • Plug-On Type CH Compatibility
  • #14-2 AWG Cu/Al Range
  • UL Listed and CSA Certified

The Eaton CH270 is a 70 A, two-pole standard-trip circuit breaker rated 120/240 V AC, with a 10 kAIC interrupt rating and common-trip operation. It uses plug-on mounting for Type CH loadcenters and is UL Listed and CSA Certified.

Product Overview

The Eaton CH270 is a 70 A, two-pole standard-trip circuit breaker rated 120/240 V AC, with a 10 kAIC interrupt rating and common-trip operation. It uses plug-on mounting for Type CH loadcenters and is UL Listed and CSA Certified.

  • 70 A, Two-Pole Common Trip
  • 120/240 V AC Rating
  • 10 kAIC Interrupt Rating
  • Plug-On Type CH Compatibility
  • #14-2 AWG Cu/Al Range
  • UL Listed and CSA Certified

Technical Specifications

Product information and specifications for the selected item.

SKU: CH270

Product Information

BrandEaton
MPNCH270
SKUCH270
UPC / GTIN782113101897
CategoryCircuit Breakers

Key Specs

Maximum Amperage (A)70
Voltage120/240 V AC
Interruption TypeStandard Trip
Breaker TypeStandard
Mounting TypePlug-On
Neutral Connection TypeNeutral

Electrical Ratings

Maximum Amperage (A)70
Voltage120/240 V AC
Interruption TypeStandard Trip
Trip curve responseAvoids nuisance tripping on mild overloads and reacts almost instantaneously to severe short-circuit conditions
Wire size range#14-2 AWG Cu/Al
Compatible Cu/Al conductor temperature60 or 75 °C
Conductor temperature class60 or 75 °C
Conductor size range#14-2 Cu/Al AWG
Interrupt rating10 kAIC
Trip characteristicInverse time element tripping operation

Breaker Configuration

Breaker TypeStandard
Mounting TypePlug-On
Neutral Connection TypeNeutral
Series TypeCH
Loadcenter restrictionNot for use in Type BR loadcentres
Handle markingsON-OFF indication and breaker ampere rating
Required panel spacesTwo 3/4-inch spaces
Handle designTrip-free handle design
Switch mechanismQuick-make, quick-break switch mechanism
Trip actionCommon trip; all poles operate simultaneously
Compatible loadcentersType CH Loadcenters
Trip arrangementCommon breaker trip
Tripped handle positionTrips to the OFF position

Pack & Smart Features

Bundle/SingleSingle Product
Pack OptionsSingle Item

Certifications

Certifications and ListingsCSA Certified, UL Listed
HACR equipment applicationMarked for heating, air conditioning and refrigeration (HACR) equipment application

Dimensions & Weight

Height (in.)2.6
Width (in.)3.2
Length (in.)1.5
Weight (lb.)0.65

Product Documents

Your cart

0 products 0 units

Your cart is empty.