The Eaton CHSPT2SURGE is a Type 2 whole-home surge protective device for 120/240 V single-phase systems. It has a 36 kA surge current per phase, 5 kA nominal discharge current, a 1,890 J rating, and a NEMA 4 enclosure. It is cUL Listed and compatible with any manufacturer's loadcenter.

  • 120/240 V Single-Phase Rating
  • 36 kA Surge Current Per Phase
  • Any-Brand Loadcenter Compatibility
  • NEMA 4 Enclosure
  • 5 kA Nominal Discharge Current
  • 1,890 J Energy Rating

The Eaton CHSPT2SURGE is a Type 2 whole-home surge protective device for 120/240 V single-phase systems. It has a 36 kA surge current per phase, 5 kA nominal discharge current, a 1,890 J rating, and a NEMA 4 enclosure. It is cUL Listed and compatible with any manufacturer's loadcenter.

Product Overview

The Eaton CHSPT2SURGE is a Type 2 whole-home surge protective device for 120/240 V single-phase systems. It has a 36 kA surge current per phase, 5 kA nominal discharge current, a 1,890 J rating, and a NEMA 4 enclosure. It is cUL Listed and compatible with any manufacturer's loadcenter.

  • 120/240 V Single-Phase Rating
  • 36 kA Surge Current Per Phase
  • Any-Brand Loadcenter Compatibility
  • NEMA 4 Enclosure
  • 5 kA Nominal Discharge Current
  • 1,890 J Energy Rating

Technical Specifications

Product information and specifications for the selected item.

SKU: CHSPT2SURGE

Product Information

BrandEaton
MPNCHSPT2SURGE
SKUCHSPT2SURGE
UPC / GTIN786685971285
CategorySurge Protective Devices

Key Specs

Surge Current Capacity (kA)36
Joules1890 J
Surge Protector Max Amperage (A)15
Connection typePanel Mount

Surge Ratings

Surge Current Capacity (kA)36
Joules1890 J
Surge Protector Max Amperage (A)15
Short-circuit current rating (SCCR)22 kA
System voltage120/240 V
Voltage protection rating (VPR)700 L-N; 1200 L-L; 900 N-G; 700 L-G V
Frequency rating60 Hz
Intended applicationProtects residential electrical and electronic loads from AC-line voltage transients and surge disturbances; intended for indoor and outdoor use.
Interrupt rating200 kAIC
Protection status indicationLED is active when protection elements are intact; an extinguished LED signals loss of protection.
Maximum continuous operating voltage (MCOV)150 L-N; 300 L-L V
Nominal discharge current5 kA
PhaseSingle-phase

Connection & Certifications

Connection typePanel Mount
Certifications and ListingscUL Listed
Loadcenter compatibilityCompatible with any manufacturer's loadcenter (breaker panel).
Enclosure ratingNEMA 4
Intended installation environmentIndoor and outdoor use
Recommended lead-wire twist rate1 twist/in
Enclosure typeNEMA 4
Product warrantyLimited lifetime
Mounting optionsMounts to the top, bottom, or sides of a loadcenter, or surface/flush mounts on the adjacent wall.
Recommended wiring lead length12 inches (30 cm) or less
Operating temperature-40 to 50 °C
ServiceabilityNot repairable; contains no user-serviceable parts; replace the unit if it fails.

Dimensions & Weight

Height (in.)2
Width (in.)5
Length (in.)7.5
Weight (lb.)0.9