The Eaton DS200EK1 is a safety-switch auxiliary contact kit with one normally open and one normally closed contact, operating in an Early-Make/Early-Break sequence. It is rated 600 V and compatible with 30–800 A safety switches except 30–100 A general-duty models, for electrical interlocking.

  • 30–800 A Switch Compatibility
  • 1NO/1NC Contact Configuration
  • 600 V Voltage Rating
  • DC Pilot-Duty Ratings
  • Early-Make/Early-Break Operation
  • UL Listed

The Eaton DS200EK1 is a safety-switch auxiliary contact kit with one normally open and one normally closed contact, operating in an Early-Make/Early-Break sequence. It is rated 600 V and compatible with 30–800 A safety switches except 30–100 A general-duty models, for electrical interlocking.

Product Overview

The Eaton DS200EK1 is a safety-switch auxiliary contact kit with one normally open and one normally closed contact, operating in an Early-Make/Early-Break sequence. It is rated 600 V and compatible with 30–800 A safety switches except 30–100 A general-duty models, for electrical interlocking.

  • 30–800 A Switch Compatibility
  • 1NO/1NC Contact Configuration
  • 600 V Voltage Rating
  • DC Pilot-Duty Ratings
  • Early-Make/Early-Break Operation
  • UL Listed

Technical Specifications

Product information and specifications for the selected item.

SKU: DS200EK1

Product Information

BrandEaton
MPNDS200EK1
SKUDS200EK1
UPC / GTIN782113208121
CategoryDevice Accessories

Accessory & Compatibility

DC pilot-duty rating at 230 VSingle throw 0.5; double throw 0.2 A
Voltage rating600 V
AC pilot-duty rating at 220 VBreak 10.0; make 20.0
ListingUL Listed
AC pilot-duty rating at 600 VBreak 5.0; make 8.0
DC pilot-duty rating at 115 VSingle throw 2.0; double throw 0.5 A
Field-installation limitationNot field-installable on shunt-trip safety switches
Contact sequencingEarly-Make/Early-Break operation
Factory installationAvailable as a factory-installed option
Contact operation sequenceEarly-Make/Early-Break
Field-installation restrictionNot field installable on shunt trip safety switches
DC pilot-duty rating at 600 VSingle throw 0.1; double throw 0.02 A
Switch amperage range30–800 A
AC pilot-duty rating at 440 VBreak 6.0; make 10.0
AC pilot-duty rating at 110 VBreak 15.0; make 40.0

Dimensions & Weight

Height (in.)2
Width (in.)4
Length (in.)5
Weight (lb.)0.4