Skip to content

Eaton Edison ECNR35 Class RK5 Dual-Element Time-Delay Fuse, 35A, 250VAC/125VDC

0 Reviews
SKU
ECNR35

The Eaton ECNR35 is a 35 A, 250 V time-delay fuse with dual elements and ferrule ends at both ends. It is current-limiting and provides motor overload, ground-fault and short-circuit protection.

  • 35 A, 250 V Time-Delay Fuse
  • 200 kAIC and 20 kA DC Interrupt Ratings
  • Motor Overload, Ground-Fault and Short-Circuit Protection
  • Current-Limiting Characteristic
  • Dual-Element Construction
  • Ferrule Ends at Both Ends

Product Overview

The Eaton ECNR35 is a 35 A, 250 V time-delay fuse with dual elements and ferrule ends at both ends. It is current-limiting and provides motor overload, ground-fault and short-circuit protection.

Technical Specifications

Product information and specifications for the selected item.

SKU: ECNR35

Product Information

BrandEaton
SKUECNR35
CategoryFuses, Fuse Blocks & Holders

Key Specs

Current - Maximum35 A
AC Voltage Rating250 V AC
DC Voltage Rating125 V DC
Fits Fuse Class or TypeClass RK5

Electrical Ratings

Current - Maximum35 A
AC Voltage Rating250 V AC
DC Voltage Rating125 V DC
Motor protectionHelps protect motors against burnout from single-phasing on three-phase systems
CSA file number700489
Compliance markingCE Marked
RoHS statusNo
Response time at 500%10 s
CSA standardCSA C22.2 No. 248.12
Motor backup sizing125% FLA for motor backup protection
Interrupt rating200 kAIC
Current-limiting characteristicYes
Interrupting rating200 kAIC
Applicable standardsUL 248-12; CSA C22.2 No. 248.12
UL standardUL 248-12
CE markingCE marked
DC interrupting rating20 kA
cULus listingListed; file No. JDDZ.E4273
Protection functionsMotor overload, ground fault and short-circuit protection
UL listingUL Listed, file E162363
Overload and surge conditionsSuitable for circuits subject to temporary motor overloads and surge currents
Recommended applicationsAC power-distribution mains, feeders and branch circuits with inductive (motors, transformers) or non-inductive (lighting, heating) loads
Minimum time-delay at 500% rated current10 s

Fuse Type & Indication

Fits Fuse Class or TypeClass RK5
Visual IndicationNon-Indicating
Number of elementsDual
Terminal configurationFerrule ends at both ends
Connection typeFerrule end x ferrule end

Dimensions & Weight

Height (in.)0.81
Width (in.)0.81
Length (in.)3
Weight (lb.)0.12

Product Documents