586-554-2000
Mon–Fri 6:30am–5pm · Sat 8am–3pm
586-554-2000
Mon–Fri 6:30am–5pm
The Eaton JDL100 is a 100 A Class J dual-element time-delay fuse rated 600 V AC and 300 V DC. It is current-limiting and non-indicating, has knife-blade terminals, and is specified for feeder and branch protection.
The Eaton JDL100 is a 100 A Class J dual-element time-delay fuse rated 600 V AC and 300 V DC. It is current-limiting and non-indicating, has knife-blade terminals, and is specified for feeder and branch protection.
The Eaton JDL100 is a 100 A Class J dual-element time-delay fuse rated 600 V AC and 300 V DC. It is current-limiting and non-indicating, has knife-blade terminals, and is specified for feeder and branch protection.
Product information and specifications for the selected item.
| Brand | Eaton |
|---|---|
| MPN | JDL100 |
| SKU | JDL100 |
| UPC / GTIN | 782634803492 |
| Category | Fuses, Fuse Blocks & Holders |
| Current - Maximum | 100 A |
|---|---|
| AC Voltage Rating | 600 V AC |
| DC Voltage Rating | 300 V DC |
| Fits Fuse Class or Type | Class J |
| Current - Maximum | 100 A |
|---|---|
| AC Voltage Rating | 600 V AC |
| DC Voltage Rating | 300 V DC |
| Suitable load applications | Inductive/high-inrush loads, including motor and motor-branch circuits and transformers; also suitable for lighting loads |
| Circuit-breaker protection application | Can be used to protect lower-interrupting-rating circuit breakers |
| Minimum time delay at 500% rated current | 10 s |
| Minimum delay at 500% of rated current | 10 seconds |
| Thermal behavior | Lower resistance than ordinary fuses, resulting in cooler operation |
| Motor-control coordination | With proper sizing, provides “No Damage” Type 2 coordinated protection for NEMA and IEC motor control per IEC 947-4-1 |
| Intended circuit application | Feeder/branch protection |
| Short-circuit protection effect | Reduces let-through thermal and magnetic forces to protect low-withstand-rated components |
| DC interrupting rating | 100 kA DC |
| Recommended load types | Inductive/high-inrush general-purpose circuits, including motor and motor-branch circuits, transformer circuits, and lighting loads. |
| Interrupting rating | 200 kAIC |
| Let-through current at 10 kA prospective short-circuit current | 2,450 A apparent RMS Sym |
| Self-certified interrupting rating | 300 kA RMS symmetrical |
| Interrupt rating | 200 kAIC |
| Fits Fuse Class or Type | Class J |
|---|---|
| Visual Indication | Non-Indicating |
| Safety certifications | UL Listed; CSA Certified |
| Current-limiting characteristic | Yes |
| Fuse action | Current-limiting |
| Compliance marks | CE Marked; RoHS Compliant |
| CSA standard | CSA C22.2 No. 248.8 |
| RoHS exemption | Exemption 6(c): copper alloy containing up to 4% lead by weight |
| Terminal style | Knife blade |
| UL standard | UL 248-8 |
| Agency certifications | UL Listed; CSA Certified |
| Applicable product standards | UL 248-8; CSA C22.2 No. 248.8 |
| Height (in.) | 1.13 |
|---|---|
| Width (in.) | 1.13 |
| Length (in.) | 4.63 |
Added to cart