Skip to content

Eaton Edison JDL100 Class J Dual-Element Time-Delay Fuse, 100A, 600VAC

0 Reviews
SKU
JDL100

The Eaton JDL100 is a 100 A Class J dual-element time-delay fuse rated 600 V AC and 300 V DC. It is current-limiting and non-indicating, has knife-blade terminals, and is specified for feeder and branch protection.

  • Class J Fuse
  • 100 A, 600 VAC / 300 VDC Ratings
  • Dual-Element Time Delay
  • Current-Limiting Action
  • Knife-Blade Terminals
  • Non-Indicating Design

The Eaton JDL100 is a 100 A Class J dual-element time-delay fuse rated 600 V AC and 300 V DC. It is current-limiting and non-indicating, has knife-blade terminals, and is specified for feeder and branch protection.

Product Overview

The Eaton JDL100 is a 100 A Class J dual-element time-delay fuse rated 600 V AC and 300 V DC. It is current-limiting and non-indicating, has knife-blade terminals, and is specified for feeder and branch protection.

  • Class J Fuse
  • 100 A, 600 VAC / 300 VDC Ratings
  • Dual-Element Time Delay
  • Current-Limiting Action
  • Knife-Blade Terminals
  • Non-Indicating Design

Technical Specifications

Product information and specifications for the selected item.

SKU: JDL100

Product Information

BrandEaton
MPNJDL100
SKUJDL100
UPC / GTIN782634803492
CategoryFuses, Fuse Blocks & Holders

Key Specs

Current - Maximum100 A
AC Voltage Rating600 V AC
DC Voltage Rating300 V DC
Fits Fuse Class or TypeClass J

Electrical Ratings

Current - Maximum100 A
AC Voltage Rating600 V AC
DC Voltage Rating300 V DC
Suitable load applicationsInductive/high-inrush loads, including motor and motor-branch circuits and transformers; also suitable for lighting loads
Circuit-breaker protection applicationCan be used to protect lower-interrupting-rating circuit breakers
Minimum time delay at 500% rated current10 s
Minimum delay at 500% of rated current10 seconds
Thermal behaviorLower resistance than ordinary fuses, resulting in cooler operation
Motor-control coordinationWith proper sizing, provides “No Damage” Type 2 coordinated protection for NEMA and IEC motor control per IEC 947-4-1
Intended circuit applicationFeeder/branch protection
Short-circuit protection effectReduces let-through thermal and magnetic forces to protect low-withstand-rated components
DC interrupting rating100 kA DC
Recommended load typesInductive/high-inrush general-purpose circuits, including motor and motor-branch circuits, transformer circuits, and lighting loads.
Interrupting rating200 kAIC
Let-through current at 10 kA prospective short-circuit current2,450 A apparent RMS Sym
Self-certified interrupting rating300 kA RMS symmetrical
Interrupt rating200 kAIC

Fuse Type & Indication

Fits Fuse Class or TypeClass J
Visual IndicationNon-Indicating
Safety certificationsUL Listed; CSA Certified
Current-limiting characteristicYes
Fuse actionCurrent-limiting
Compliance marksCE Marked; RoHS Compliant
CSA standardCSA C22.2 No. 248.8
RoHS exemptionExemption 6(c): copper alloy containing up to 4% lead by weight
Terminal styleKnife blade
UL standardUL 248-8
Agency certificationsUL Listed; CSA Certified
Applicable product standardsUL 248-8; CSA C22.2 No. 248.8

Dimensions & Weight

Height (in.)1.13
Width (in.)1.13
Length (in.)4.63

Product Documents