The Eaton GF20BK is a black, slim-design 20 A, 125 V grounded duplex GFCI receptacle with a NEMA 5-20R configuration. It features self-test operation, screw terminals for backwire or sidewire connections, an indicator light, and a pop-out feature.

  • 20 A, 125 V Rating
  • NEMA 5-20R Configuration
  • Self-Test GFCI Function
  • Back/Side-Wire Screw Terminals
  • Black Slim Design
  • Indicator Light and Pop-Out

Product Overview

The Eaton GF20BK is a black, slim-design 20 A, 125 V grounded duplex GFCI receptacle with a NEMA 5-20R configuration. It features self-test operation, screw terminals for backwire or sidewire connections, an indicator light, and a pop-out feature.

Technical Specifications

Product information and specifications for the selected item.

SKU: GF20BK

Product Information

BrandEaton
MPNGF20BK
SKUGF20BK
UPC / GTIN032664012372
CategoryReceptacles & Outlets

Key Specs

Amperage (A)20
Voltage (V)125 V
NEMA ConfigurationNEMA 5-20R
Safety RatingGFCI, Grounded
Wire Connection TypeScrew Terminal

Electrical Ratings

Amperage (A)20
Voltage (V)125 V
Dielectric voltage withstand2000 V
Overload-test temperature riseMax. 30 after 100 cycles at 150% of rated current (DC) °C
Frequency60 Hz
Short-circuit testing threshold10 kA
GFCI trip time0.025 seconds
Short-circuit current rating10 kA
Temperature rating-35 to 66 °C

Configuration & Wiring

NEMA ConfigurationNEMA 5-20R
Wire Connection TypeScrew Terminal
Backwire strip length11/16 in
Terminal identificationGreen = grounding; silver = white; brass = hot
Initial reset conditionShips tripped; reset only after correct wiring and power from the LINE terminals
Allowable wire size#14-10 AWG
Torque rating16 lbf-in
Sidewire strip length7/8 in
Terminal screw torque16 lbf-in
Permitted conductor materialCopper or copper-clad wire only; do not use aluminum wire

Safety & Compatibility

Safety RatingGFCI, Grounded
Flammability classificationV2
Recommended test intervalPress TEST, then RESET, every month
RESET lockout conditionsRESET is prevented if power is absent, LINE/LOAD are reversed, or the internal self-test fails
Protection limitationDoes not protect against circuit overloads or short circuits
CertificationNOM certified
Life-support circuit restrictionDo not install on a circuit powering life-support equipment; a trip shuts down the equipment

Features & Finish

FeaturesIndicator Light, Pop-Out
Wall Plate IncludedNo Wall Plate
Color FamilyBlack
Bundle/SingleSingle Product
End-of-life indicationRed indicator; flashing or continuous illumination means replace the unit

Dimensions & Weight

Height (in.)4.19
Width (in.)1.69
Length (in.)1.03

Product Documents