Skip to content

Eaton HKD3400F Series C K-Frame Circuit Breaker Frame Only, 400A, 3P

0 Reviews
SKU
HKD3400F

The Eaton HKD3400F is a 400 A, three-pole Series C HKD K-frame molded-case circuit breaker frame with bolt-on mounting. It is identified as frame-only; trip units and terminals are ordered as individual components.

  • 400 A, Three-Pole Frame
  • 600 VAC / 250 VDC Ratings
  • Interrupting Capacity Ratings
  • Bolt-On Mounting
  • Trip-Unit Configurations
  • UL Listed

The Eaton HKD3400F is a 400 A, three-pole Series C HKD K-frame molded-case circuit breaker frame with bolt-on mounting. It is identified as frame-only; trip units and terminals are ordered as individual components.

Product Overview

The Eaton HKD3400F is a 400 A, three-pole Series C HKD K-frame molded-case circuit breaker frame with bolt-on mounting. It is identified as frame-only; trip units and terminals are ordered as individual components.

  • 400 A, Three-Pole Frame
  • 600 VAC / 250 VDC Ratings
  • Interrupting Capacity Ratings
  • Bolt-On Mounting
  • Trip-Unit Configurations
  • UL Listed

Technical Specifications

Product information and specifications for the selected item.

SKU: HKD3400F

Product Information

BrandEaton
MPNHKD3400F
SKUHKD3400F
UPC / GTIN786679661956
CategoryCircuit Breakers

Key Specs

Maximum Amperage (A)400
Voltage600 V AC
Interruption TypeStandard Trip
Breaker TypeStandard
Mounting TypeBolt-On

Electrical Ratings

Maximum Amperage (A)400
Voltage600 V AC
Interruption TypeStandard Trip
Thermal calibrationThermally uncompensated; calibrated at 40°C to Option B requirements for thermal-magnetic devices.
Frequency rating50 to 60 Hz

Breaker Configuration

Breaker TypeStandard
Mounting TypeBolt-On
Series TypeSeries C
Trip mechanism descriptionFixed thermal; fixed magnetic
Single-phase useThree-pole breakers can be used on single-phase AC circuits using the two outside poles.
Reverse-feed suitabilitySuitable for reversed line/load connections.
Manufacturer trip-type codeT186
Assembly componentsFrame, trip unit, and terminals are ordered as individual components.
Trip characteristicsFixed thermal, fixed magnetic; type designation T186
Trip-unit compatibilityThe frame supports thermal-magnetic or 310+ electronic trip-unit configurations.
Trip-free operationOn automatic tripping, the handle assumes a mid-position between ON and OFF; the mechanism is trip-free.
Conductor compatibilityHKD breaker configurations are suitable for copper and aluminum conductors rated 75°C.
Push-to-tripIncludes a push-to-trip feature.

Pack & Smart Features

Bundle/SingleSingle Product
Pack OptionsSingle Item

Certifications

Certifications and ListingsUL Listed

Dimensions & Weight

Height (in.)5.5
Width (in.)5.5
Length (in.)4.1
Weight (lb.)9.8

Product Documents

Your cart

0 products 0 units

Your cart is empty.

Add products as you browse, then review them here.