Skip to content

Eaton Series C GHBGFEP 20A 1P Bolt-On 30mA Ground-Fault Equipment Protection Circuit Breaker

0 Reviews
SKU
GHBGFEP1020

The Eaton Series C GHBGFEP1020 is a 20 A, single-pole, bolt-on molded-case circuit breaker for ground-fault equipment protection. It has a 30 mA trip level, 480Y/277 V AC and 125/250 V DC ratings, 14 kAIC interrupting capacity at 277 V AC, a fixed thermal-magnetic trip, and a pigtail neutral.

  • 20 A, single-pole rating
  • 30 mA ground-fault trip
  • 480Y/277 V AC and 125/250 V DC ratings
  • 14 kAIC at 277 V AC
  • Bolt-on mounting
  • Pigtail neutral connection

The Eaton Series C GHBGFEP1020 is a 20 A, single-pole, bolt-on molded-case circuit breaker for ground-fault equipment protection. It has a 30 mA trip level, 480Y/277 V AC and 125/250 V DC ratings, 14 kAIC interrupting capacity at 277 V AC, a fixed thermal-magnetic trip, and a pigtail neutral.

Product Overview

The Eaton Series C GHBGFEP1020 is a 20 A, single-pole, bolt-on molded-case circuit breaker for ground-fault equipment protection. It has a 30 mA trip level, 480Y/277 V AC and 125/250 V DC ratings, 14 kAIC interrupting capacity at 277 V AC, a fixed thermal-magnetic trip, and a pigtail neutral.

  • 20 A, single-pole rating
  • 30 mA ground-fault trip
  • 480Y/277 V AC and 125/250 V DC ratings
  • 14 kAIC at 277 V AC
  • Bolt-on mounting
  • Pigtail neutral connection

Technical Specifications

Product information and specifications for the selected item.

SKU: GHBGFEP1020

Product Information

BrandEaton
MPNGHBGFEP1020
SKUGHBGFEP1020
UPC / GTIN786679067437
CategoryCircuit Breakers

Key Specs

Maximum Amperage (A)20
Voltage277 V AC
Interruption TypeGFPE
Breaker TypeStandard
Mounting TypeBolt-On
Neutral Connection TypePigtail

Electrical Ratings

Maximum Amperage (A)20
Voltage277 V AC
Interruption TypeGFPE
120/208 V panel compatibilityNot compatible; insufficient voltage to power the ground-fault sensor
Frequency rating50/60 Hz
Interrupting capacity14 kAIC at 277 Vac
Short-circuit interrupting rating14 kAIC at 277 Vac

Breaker Configuration

Breaker TypeStandard
Mounting TypeBolt-On
Neutral Connection TypePigtail
Series TypeSeries C
Trip mechanismFixed thermal, fixed magnetic
Frame sizeG-frame
Terminal body materialSteel
Trip-unit configurationNon-interchangeable
Terminal conductor rangeCopper/aluminum conductors, #14–10 (one conductor) AWG

Pack & Smart Features

Bundle/SingleSingle Product
Pack OptionsSingle Item

Certifications

Certifications and ListingsUL Listed

Dimensions & Weight

Height (in.)4
Width (in.)1
Length (in.)2.63
Weight (lb.)1.5

Product Documents

Your cart

1 product 1 unit