The Eaton HFD3030 is a Series C F-frame molded-case circuit breaker rated 30 A with three poles and a fixed thermal-magnetic trip. It is UL Listed and rated for 600 VAC/250 VDC; 250 VDC service uses two poles.

  • 30 A Maximum Amperage
  • Three-Pole Configuration
  • 600 VAC / 250 VDC Ratings
  • Voltage-Specific Interrupt Ratings
  • Fixed Thermal-Magnetic Trip
  • Load-Side Terminal Location

The Eaton HFD3030 is a Series C F-frame molded-case circuit breaker rated 30 A with three poles and a fixed thermal-magnetic trip. It is UL Listed and rated for 600 VAC/250 VDC; 250 VDC service uses two poles.

Product Overview

The Eaton HFD3030 is a Series C F-frame molded-case circuit breaker rated 30 A with three poles and a fixed thermal-magnetic trip. It is UL Listed and rated for 600 VAC/250 VDC; 250 VDC service uses two poles.

  • 30 A Maximum Amperage
  • Three-Pole Configuration
  • 600 VAC / 250 VDC Ratings
  • Voltage-Specific Interrupt Ratings
  • Fixed Thermal-Magnetic Trip
  • Load-Side Terminal Location

Technical Specifications

Product information and specifications for the selected item.

SKU: HFD3030

Product Information

BrandEaton
MPNHFD3030
SKUHFD3030
UPC / GTIN786679175804
CategoryCircuit Breakers

Key Specs

Maximum Amperage (A)30
Voltage600 V
Interruption TypeStandard Trip
Breaker TypeStandard
Neutral Connection TypeNon-Neutral

Electrical Ratings

Maximum Amperage (A)30
Voltage600 V
Interruption TypeStandard Trip
Trip characteristicsFixed thermal, fixed magnetic
Interrupting rating at 240 Vac100 kAIC
DC magnetic behaviorApproximately 40% higher
Frequency rating50/60 Hz
Interrupting rating at 480 Vac65 kAIC
Continuous-current rating reference temperature40 °C
Interrupting rating at 600 Vac25 kAIC
Interrupting rating at 250 Vdc (two poles of a three-pole breaker)22 kA

Breaker Configuration

Breaker TypeStandard
Neutral Connection TypeNon-Neutral
Series TypeSeries C
DC pole configurationFor 250 Vdc, use a two-pole breaker or two poles of a three-pole breaker
Terminal side providedLoad side
Trip unit interchangeabilityNon-interchangeable thermal-magnetic trip unit
Terminal locationLoad side
Reverse-feed suitabilitySuitable for reverse feed use
Trip-type codeT186

Pack & Smart Features

Bundle/SingleSingle Product

Certifications

Certifications and ListingsUL Listed
HID-use suitabilitySuitable for HID (high intensity discharge) use
HACR ratingHACR rated

Dimensions & Weight

Height (in.)6
Width (in.)4.13
Length (in.)3.38
Weight (lb.)4.3