Skip to content

Eaton Type BR Plug-On Surge Protective Device, UL Classified, Clamshell

0 Reviews
SKU
CLNSURGECS

Eaton CLNSURGECS is a Type BR plug-on, Type 2 surge protective device for 120/240 V AC single split-phase systems. It provides line-to-neutral and line-to-line protection and is rated for 18 kA surge current, 3 kA nominal discharge current, 600 V measured limiting voltage, and 10 kA short-circuit current.

  • Compatible Loadcenters
  • Type BR Plug-On Connection
  • 120/240V Single Split-Phase
  • 18 kA Surge Current
  • L-N and L-L Protection
  • Type 2, UL Classified

Eaton CLNSURGECS is a Type BR plug-on, Type 2 surge protective device for 120/240 V AC single split-phase systems. It provides line-to-neutral and line-to-line protection and is rated for 18 kA surge current, 3 kA nominal discharge current, 600 V measured limiting voltage, and 10 kA short-circuit current.

Product Overview

Eaton CLNSURGECS is a Type BR plug-on, Type 2 surge protective device for 120/240 V AC single split-phase systems. It provides line-to-neutral and line-to-line protection and is rated for 18 kA surge current, 3 kA nominal discharge current, 600 V measured limiting voltage, and 10 kA short-circuit current.

  • Compatible Loadcenters
  • Type BR Plug-On Connection
  • 120/240V Single Split-Phase
  • 18 kA Surge Current
  • L-N and L-L Protection
  • Type 2, UL Classified

Technical Specifications

Product information and specifications for the selected item.

SKU: CLNSURGECS

Product Information

BrandEaton
MPNCLNSURGECS
SKUCLNSURGECS
UPC / GTIN786689353735
CategorySurge Protective Devices

Key Specs

Surge Current Capacity (kA)18
Connection typeBreaker

Surge Ratings

Surge Current Capacity (kA)18
Maximum continuous operating voltage (MCOV)150 L-N; 300 L-L V
Protection modesL-N, L-L
Short-circuit rating (SCCR)10 kA
Protection-status indicatorSingle status LED
Direct-lightning limitationDoes not protect against direct lightning strikes
Power-up operationAutomatically begins protecting downstream electrical devices after system power is applied
Measured limiting voltage600 V
Nominal discharge current (In)3 kA
LED status behaviorLED is active when all protection elements are intact with all phase voltages present; it extinguishes to signal loss of protection

Connection & Certifications

Connection typeBreaker
Certifications and ListingscUL Listed, UL Classified, UL Listed
Compatible loadcentersEaton Type BR, Eaton Cutler-Hammer Type BR, Challenger, and Westinghouse loadcenters
SPD typeType 2
System voltage and phase120/240, single split-phase V AC
Limited product warranty1 year
Neutral lead installationTrim the white lead to the shortest required length and connect it to the panel neutral bus.
Input power frequency50/60 Hz
Frequency rating50/60 Hz
Type 2 installation locationLoad side of the service entrance overcurrent protective device, including at the branch panel
Phase configurationSingle split-phase
ServiceabilityNot repairable and contains no user-serviceable parts; replace if the unit fails

Dimensions & Weight

Height (in.)2.981
Width (in.)1.98
Length (in.)3
Weight (lb.)0.35

Product Documents