The white First Alert SM2-W10-T is a hardwired photoelectric smoke alarm with a sealed, non-replaceable 10-year lithium-ion battery backup and an included quick-connect plug. It is UL certified, supports interconnection, and measures 5.2 in. wide Ă— 5.2 in. long Ă— 1.76 in. high.
Photoelectric Smoke Detection
120 VAC Hardwired Supply
Sealed 10-Year Battery Backup
Interconnection Capacity
Quick-Connect Plug Included
UL Certified
The white First Alert SM2-W10-T is a hardwired photoelectric smoke alarm with a sealed, non-replaceable 10-year lithium-ion battery backup and an included quick-connect plug. It is UL certified, supports interconnection, and measures 5.2 in. wide Ă— 5.2 in. long Ă— 1.76 in. high.
The white First Alert SM2-W10-T is a hardwired photoelectric smoke alarm with a sealed, non-replaceable 10-year lithium-ion battery backup and an included quick-connect plug. It is UL certified, supports interconnection, and measures 5.2 in. wide Ă— 5.2 in. long Ă— 1.76 in. high.
Photoelectric Smoke Detection
120 VAC Hardwired Supply
Sealed 10-Year Battery Backup
Interconnection Capacity
Quick-Connect Plug Included
UL Certified
Technical Specifications
Product information and specifications for the selected item.
SKU: SM2-W10-T
Product Information
Brand
First Alert
MPN
SM2-W10-T
SKU
SM2-W10-T
UPC / GTIN
194160017296
Category
Safety Supplies
Key Specs
Certifications and Listings
UL Certified
Bundle/Single
Single Product
Safety & Compliance
Certifications and Listings
UL Certified
Compatible smart alarm
SC5 Smart Smoke & CO Alarm
Installer requirement
Wiring and installation must be performed by a licensed electrician
Smoke alarm signal pattern
3-pulse temporal pattern
Operating temperature range
40–100 °F (4.4–38 °C)
Interconnect circuit requirement
All interconnected units must share the same fuse or circuit breaker
Operating humidity range
20–95% RH, non-condensing (93% maximum for agency compliance)
Audible alarm level
85 dB minimum at 10 feet (3 meters)
Interconnect wiring requirements
All interconnected units must share a fuse or circuit breaker; total interconnect wire length under 1,000 ft (300 m)
Required power circuit
24-hour 120 VAC, 60 Hz pure sine wave circuit; must not be switched, dimmed, or GFCI-controlled
Maximum interconnect wire length
Less than 1,000 ft (300 m)
Intended environment
Ordinary indoor residential areas
Storage temperature range
14–158 °F (-10–70 °C)
Battery replaceable
No
Mounting compatibility
Standard wiring junction box up to 4 in. (10 cm); ceiling or wall mounting where local codes allow
Backup battery chemistry
Lithium-ion, non-replaceable
Ceiling fan and register clearance
Do not install within 36 inches of ceiling fans or supply registers
Alarm replacement interval
Replace the alarm every 10 years
Maximum interconnected units
18 total; maximum 12 smoke alarms
Maximum interconnect capacity
Maximum 18 compatible units total, including a maximum of 12 smoke alarms
Mounting instruction
Mount flush to the electrical box to prevent air leaks between the ceiling and bracket
AC power rating
120 VAC @ 60 Hz, 0.7 A
Smoke sensitivity
2.4%/ft obscuration ±25%
Compatible interconnection devices
Compatible with First Alert and BRK smoke and heat alarms, and Smart Interconnect CO alarms
Battery type
Lithium
Package & Appearance
Bundle/Single
Single Product
Hardware Color Family
White
Dimensions & Weight
Height (in.)
1.76
Width (in.)
5.2
Length (in.)
5.2
Weight (lb.)
0.48
Product Documents