First Alert SMCO210 2-in-1 Smoke and Carbon Monoxide Alarm, 10-Year Battery
0 Reviews
SKU
1046796
The First Alert SMCO210 combines photoelectric smoke sensing and electrochemical carbon monoxide sensing in a slim-profile alarm. It uses a sealed, nonreplaceable 10-year lithium battery and includes a test/silence button and end-of-life warning.
Photoelectric Smoke Sensing
Electrochemical CO Sensing
Sealed 10-Year Lithium Battery
Test/Silence Button
End-of-Life Warning
UL Certified
The First Alert SMCO210 combines photoelectric smoke sensing and electrochemical carbon monoxide sensing in a slim-profile alarm. It uses a sealed, nonreplaceable 10-year lithium battery and includes a test/silence button and end-of-life warning.
The First Alert SMCO210 combines photoelectric smoke sensing and electrochemical carbon monoxide sensing in a slim-profile alarm. It uses a sealed, nonreplaceable 10-year lithium battery and includes a test/silence button and end-of-life warning.
Photoelectric Smoke Sensing
Electrochemical CO Sensing
Sealed 10-Year Lithium Battery
Test/Silence Button
End-of-Life Warning
UL Certified
Technical Specifications
Product information and specifications for the selected item.
SKU: 1046796
Product Information
Brand
First Alert
MPN
1046796
SKU
1046796
UPC / GTIN
029054022073
Category
Safety Supplies
Key Specs
Safety Features
Other
Certifications and Listings
UL Certified
Bundle/Single
Single Product
Safety & Compliance
Safety Features
Other
Certifications and Listings
UL Certified
Battery activation
Mounting the alarm to the bracket activates the battery; once activated, the unit cannot be turned off
CO alarm response at 400 ppm
At 400 ppm CO, must alarm between 4 and 15 minutes
Routine maintenance schedule
Test at least weekly; clean at least monthly
Power-outage operation
Provides protection during an electricity failure when batteries are fresh and correctly installed
Interconnection
Does not provide interconnected functionality
Intended use
Approved for single-family residences; not designed for marine or RV use
Mounting orientation
Ceiling or wall mounting; not a tabletop device
Response to constant 30 ppm CO
Designed not to alarm at a constant 30 ppm for 30 days
Cooking-appliance clearance
Avoid installation within 5 ft (1.5 m) of a cooking appliance
Limited warranty period
10 years from date of purchase
CO alarm response at 150 ppm
At 150 ppm CO, must alarm between 10 and 50 minutes
Audible alarm level
85 minimum at 10 ft (3 m) dB
Recommended installation temperature
40–100 °F (4.4–37.8 °C)
Industrial CO measurement
Not designed to measure CO levels to OSHA commercial or industrial standards
CO alarm response at 70 ppm
At 70 ppm CO, must alarm between 60 and 240 minutes
Battery serviceability
Sealed alarm with no serviceable parts; battery is not replaceable
Fluorescent-light clearance
At least 12 in (305 mm) from fluorescent lights
Replacement interval from installation
10 years
Combustion-source clearance
At least 20 ft (6 m) from combustion sources, if possible