Generac’s RTSW100K3 is an automatic, service-entrance-rated transfer switch for 100 A, 277/480 V three-phase systems. It supports a maximum wattage of 24 kW and is specified for three-phase generators using Evolution™ or Nexus™ controllers, with a NEMA 3R, water-resistant enclosure.
Generac’s RTSW100K3 is an automatic, service-entrance-rated transfer switch for 100 A, 277/480 V three-phase systems. It supports a maximum wattage of 24 kW and is specified for three-phase generators using Evolution™ or Nexus™ controllers, with a NEMA 3R, water-resistant enclosure.
Generac’s RTSW100K3 is an automatic, service-entrance-rated transfer switch for 100 A, 277/480 V three-phase systems. It supports a maximum wattage of 24 kW and is specified for three-phase generators using Evolution™ or Nexus™ controllers, with a NEMA 3R, water-resistant enclosure.
Product information and specifications for the selected item.
| Brand | Generac |
|---|---|
| MPN | RTSW100K3 |
| SKU | RTSW100K3 |
| UPC / GTIN | 696471620450 |
| Category | Automatic Transfer Switches |
| Maximum Amperage (A) | 100 |
|---|---|
| Maximum Wattage (W) | 24000 |
| Automatic/Manual | Automatic |
| Maximum Amperage (A) | 100 |
|---|---|
| Maximum Wattage (W) | 24000 |
| Rated voltage and phase | 277/480 V, three-phase |
| Utility voltage pickup threshold | >90 % |
| Neutral Arrangement | Three-phase neutral connects to a neutral lug and is not switched |
| Utility voltage drop-out threshold | <60 % |
| Utility Service Circuit Breaker | Type 225AF, 3-pole; 50/60 Hz |
| Transfer-switch lug range | #6 AWG - 2/O |
| Withstand rating | 14 kA |
| Service rating | Service-rated (RTSW) |
| Breaker lug range | #6 AWG - 300MCM |
| Service Breaker Line Conductor Range | 6 STR to 300 MCM (Cu/Al) |
| Automatic/Manual | Automatic |
|---|---|
| Features | Water Resistant |
| Exerciser schedule | Nexus™: 12 minutes weekly; Evolution™: 5 to 12 minutes adjustable, weekly/bi-weekly/monthly |
| Engine warmup delay | 5 factory-set; adjustable from 2 to 1,500 by a qualified dealer when used with Evolution™ controls seconds |
| Engine cooldown timer | 60 seconds; 5 minutes on turbo configuration |
| Control source | Controller at the generator handles timing, sensing, exercising, and transfer commands |
| Re-transfer time delay | 15 seconds |
| Generator/controller compatibility | For three-phase generators using Evolution™ or Nexus™ controllers |
| Enclosure finish | Electrostatically applied powder coating |
| Load transition type | Open transition |
| Installation design | Designed for a single-person installation |
| Enclosure material | Aluminum |
| Enclosure design | Integrated deadfront for safe operation of the service disconnect |
| Timer to generator start | 5 factory-set; adjustable from 2 to 1,500 by a qualified dealer when used with Evolution™ controls seconds |
| Enclosure type | NEMA 3R |
|---|---|
| Service Entrance Rating | Service entrance rated |
| Height (in.) | 48 |
|---|---|
| Width (in.) | 21.8 |
| Length (in.) | 10.1 |
| Weight (lb.) | 50 |
Added to cart