586-554-2000
Mon–Fri 6:30am–5pm · Sat 8am–3pm
586-554-2000
Mon–Fri 6:30am–5pm
The Generac RTSC400A3 is a 400 A automatic transfer switch for 120/240 V, single-phase optional standby systems. It is non-service-entrance-rated, uses open-transition transfer, and has a NEMA 3R enclosure with an integrated Smart A/C module for up to four HVAC loads.
The Generac RTSC400A3 is a 400 A automatic transfer switch for 120/240 V, single-phase optional standby systems. It is non-service-entrance-rated, uses open-transition transfer, and has a NEMA 3R enclosure with an integrated Smart A/C module for up to four HVAC loads.
The Generac RTSC400A3 is a 400 A automatic transfer switch for 120/240 V, single-phase optional standby systems. It is non-service-entrance-rated, uses open-transition transfer, and has a NEMA 3R enclosure with an integrated Smart A/C module for up to four HVAC loads.
Product information and specifications for the selected item.
| Brand | Generac |
|---|---|
| MPN | RTSC400A3 |
| SKU | RTSC400A3 |
| UPC / GTIN | 696471619867 |
| Category | Automatic Transfer Switches |
| Maximum Amperage (A) | 400 |
|---|---|
| Automatic/Manual | Automatic |
| Maximum Amperage (A) | 400 |
|---|---|
| Short-circuit withstand rating | 22,000 A |
| Power conductor range | (1) #4–600 MCM Cu/Al or (2) 1/0–250 MCM Cu/Al |
| Compatible load types | Motors, electric discharge lamps, tungsten filament, and electric heating equipment |
| Withstand current rating | 22,000 A |
| Neutral switching | Neutral connects to a neutral lug and is not switched |
| Power-conductor lug torque | 375 in-lbs |
| A/C control contact rating | 24 VAC, 1.0 A maximum |
| Tungsten load limit | Tungsten load must not exceed 30% of switch rating |
| Power terminal type | Solderless, screw-type lugs |
| Auxiliary contact rating | 10 amps at 125 or 250 volts AC |
| Automatic/Manual | Automatic |
|---|---|
| Features | Mountable, On Indicator Light, Overload Protection, Water Resistant |
| Generator-start timer adjustment range | Adjustable from 2 to 1,500 seconds by a qualified dealer with Evolution™ controls |
| Engine warmup delay | 5 seconds |
| Enclosure material | Steel |
| Re-transfer time delay | 15 seconds |
| Utility voltage pickup threshold | >80 % |
| Generator controller compatibility | Evolution™ or Nexus™ generator controllers |
| Load transition type | Open transition |
| Mounting orientation | Mount vertically on a rigid supporting structure |
| Engine cooldown timer | 60 seconds |
| Timing and sensing control source | Generator controller |
| Standby voltage sensor threshold | 60% for 5 seconds |
| Exerciser schedule | Nexus™: 12 minutes weekly; Evolution™: adjustable 5–12 minutes, weekly/bi-weekly/monthly |
| Utility voltage drop-out threshold | <60 % |
| Permitted system use | Optional standby systems only (NEC Article 702) |
|---|
| Height (in.) | 36 |
|---|---|
| Width (in.) | 24 |
| Length (in.) | 10 |
Added to cart