Generac's RTSN100J3 is a 100 A automatic, open-transition transfer switch rated 120/240 V, three-phase. It is non-service-entrance and non-fused, with a water-resistant steel NEMA 3R enclosure for indoor and outdoor use.

  • 100 A, 120/240 V Three-Phase
  • Automatic Open-Transition Operation
  • Non-Service-Entrance, Non-Fused
  • Steel NEMA 3R Enclosure
  • All Load Classes
  • UL and cUL Listed

Generac's RTSN100J3 is a 100 A automatic, open-transition transfer switch rated 120/240 V, three-phase. It is non-service-entrance and non-fused, with a water-resistant steel NEMA 3R enclosure for indoor and outdoor use.

Product Overview

Generac's RTSN100J3 is a 100 A automatic, open-transition transfer switch rated 120/240 V, three-phase. It is non-service-entrance and non-fused, with a water-resistant steel NEMA 3R enclosure for indoor and outdoor use.

  • 100 A, 120/240 V Three-Phase
  • Automatic Open-Transition Operation
  • Non-Service-Entrance, Non-Fused
  • Steel NEMA 3R Enclosure
  • All Load Classes
  • UL and cUL Listed

Technical Specifications

Product information and specifications for the selected item.

SKU: RTSN100J3

Product Information

BrandGenerac
MPNRTSN100J3
SKURTSN100J3
UPC / GTIN696471110432
CategoryAutomatic Transfer Switches

Key Specs

Maximum Amperage (A)100
FusedNon-Fused
Automatic/ManualAutomatic
Certifications and ListingscUL Listed, UL Listed

Electrical Ratings

Maximum Amperage (A)100
FusedNon-Fused
Load ratingAll load classes; 100% equipment-rated for inductive and resistive loads
Lug range2/0 - #6
Terminal lug constructionSolderless, screw-type terminal lugs
Voltage and phase120/240 3Ø V
Withstand rating14,000 A

Transfer & Features

Automatic/ManualAutomatic
FeaturesWater Resistant
Load transition typeOpen transition
Utility voltage drop-out threshold<60 %
Enclosure materialSteel
Contact mechanismElectrically operated; mechanically held
Standby voltage sensor60% for 5 seconds
Main contact materialSilver plated or silver alloy
Generator start delay10 seconds factory-set; adjustable 2–30 seconds by a qualified dealer when used with Evolution controls
Neutral switchingThe three-phase neutral connects to a neutral lug and is not switched
Engine cooldown timer60 seconds
Utility voltage dropout<60 %
Utility voltage pickup threshold>80 %
Exerciser scheduleNexus™: 12 minutes weekly; Evolution™: 5 to 12 minutes adjustable, weekly/bi-weekly/monthly
Re-transfer time delay15 seconds
Timing and sensing control sourceGenerator controller
Timer to generator start10 factory-set; adjustable 2–30 by a qualified dealer when used with Evolution™ controls seconds
Enclosure finishElectrostatically applied and baked powder paint
Engine warmup delay5 seconds
Coil configurationSingle coil

Certifications

Certifications and ListingscUL Listed, UL Listed
Enclosure ratingNEMA 3R, indoor/outdoor rated

Dimensions & Weight

Height (in.)24.1
Width (in.)20.2
Length (in.)7.1
Weight (lb.)57