Generac RTSN200K3 200A 277/480V 3-Phase Non-Service-Entrance Automatic Transfer Switch

0 Reviews
SKU
RTSN200K3

The Generac RTSN200K3 is an automatic 200 A transfer switch for 277/480 V three-phase service, specified as non-service-entrance with open-transition operation. It has a steel NEMA 3R enclosure for indoor or outdoor installation, is UL Listed and cUL Listed, and is 100% equipment-rated for all load classes, inductive and resistive. Its solderless, screw-type terminal lugs accept #4 AWG to 400 MCM conductors.

  • 200 A maximum rating
  • 277/480 V, three-phase service
  • Non-service-entrance rating
  • Open-transition switching
  • Steel NEMA 3R enclosure
  • Terminal lugs #4 AWG to 400 MCM

Product Overview

The Generac RTSN200K3 is an automatic 200 A transfer switch for 277/480 V three-phase service, specified as non-service-entrance with open-transition operation. It has a steel NEMA 3R enclosure for indoor or outdoor installation, is UL Listed and cUL Listed, and is 100% equipment-rated for all load classes, inductive and resistive. Its solderless, screw-type terminal lugs accept #4 AWG to 400 MCM conductors.

Technical Specifications

Product information and specifications for the selected item.

SKU: RTSN200K3

Product Information

BrandGenerac
MPNRTSN200K3
SKURTSN200K3
UPC / GTIN696471112337
CategoryAutomatic Transfer Switches

Key Specs

Maximum Amperage (A)200
Automatic/ManualAutomatic
Certifications and ListingscUL Listed, UL Listed

Electrical Ratings

Maximum Amperage (A)200
Lug conductor range#4 AWG to 400 MCM
Terminal Lug Range400 MCM - #4
Load rating100% equipment-rated for all classes of load, inductive and resistive
Main contact materialSilver plated or silver alloy
Neutral configuration3-pole mechanism; neutral connects to a neutral lug and is not switched
Withstand rating25,000 A
Terminal typeSolderless, screw-type terminal lugs

Transfer & Features

Automatic/ManualAutomatic
FeaturesWater Resistant
Control interconnection wiringUtility 1 and 2, plus leads 23 and 194; run in a conduit separate from AC power leads
Control functions handled at generatorGenerator controller handles timing, sensing, exercising, and transfer commands
Contact OperationElectrically operated, mechanically held
Generator Start Delay10 factory-set; adjustable 2–30 by a qualified dealer when used with Evolution controls
Engine Warmup Delay5 s
Transfer time160 ms
Load transition typeOpen transition
Enclosure finishElectrostatically applied and baked powder paint
Recommended control wire size by run lengthNo. 18 AWG for 1–115 ft; No. 16 AWG for 116–185 ft; No. 14 AWG for 186–295 ft; No. 12 AWG for 296–460 ft
Control ArchitectureGenerator controller handles timing, sensing, exercising functions, and transfer commands
Enclosure construction and ratingSteel NEMA 3R enclosure; indoor/outdoor rated
Enclosure MaterialSteel
Utility Voltage Drop-out<60 %

Certifications

Certifications and ListingscUL Listed, UL Listed

Dimensions & Weight

Height (in.)48.1
Width (in.)30.1
Length (in.)13.1
Weight (lb.)105
Electrical clearanceAt least 1/2 in
Conduit entriesThree triple EKO entries for 1-, 1.25-, or 1.50-in conduit
Mounting orientationMount vertically on a rigid supporting structure
Mounting hole patternFour Ø0.25-in (6.35-mm) mounting holes