Generac RTSW200J3 200A 120/240V 3-Phase Service-Entrance-Rated Automatic Transfer Switch
0 Reviews
SKU
RTSW200J3
The Generac RTSW200J3 is an automatic 200 A, 120/240 V three-phase transfer switch with a service-entrance rating, non-fused construction and a NEMA 3R indoor/outdoor enclosure. It is designed for three-phase generators using Evolution or Nexus controllers.
200 A Automatic Transfer
120/240 V Three-Phase
Service-Entrance Rated
Non-Fused Construction
NEMA 3R Enclosure
Evolution/Nexus Controller Compatibility
The Generac RTSW200J3 is an automatic 200 A, 120/240 V three-phase transfer switch with a service-entrance rating, non-fused construction and a NEMA 3R indoor/outdoor enclosure. It is designed for three-phase generators using Evolution or Nexus controllers.
The Generac RTSW200J3 is an automatic 200 A, 120/240 V three-phase transfer switch with a service-entrance rating, non-fused construction and a NEMA 3R indoor/outdoor enclosure. It is designed for three-phase generators using Evolution or Nexus controllers.
200 A Automatic Transfer
120/240 V Three-Phase
Service-Entrance Rated
Non-Fused Construction
NEMA 3R Enclosure
Evolution/Nexus Controller Compatibility
Technical Specifications
Product information and specifications for the selected item.
SKU: RTSW200J3
Product Information
Brand
Generac
MPN
RTSW200J3
SKU
RTSW200J3
UPC / GTIN
696471620474
Category
Automatic Transfer Switches
Key Specs
Maximum Amperage (A)
200
Fused
Non-Fused
Automatic/Manual
Automatic
Electrical Ratings
Maximum Amperage (A)
200
Fused
Non-Fused
Terminal lug construction
Solderless, screw-type terminal lugs
Short-circuit withstand rating
18 kA
Utility breaker lug range
#6 AWG–300 MCM AWG/MCM
Tungsten load limit
30 % of switch rating
Supported load types
Motors, electric-discharge lamps, tungsten filament, and electric-heating equipment
Neutral-to-enclosure bonding jumper
Factory-installed between the neutral lug and enclosure; removable
Utility service breaker type and poles
Type 225AF, 3-pole
Transfer-switch lug conductor range
#4 AWG–400 MCM AWG/MCM
Transfer-switch terminal torque
275 in-lb (31.1 Nm)
Recommended control-wire sizing by run length
18 AWG for 1–115 ft (1–35 m); 16 AWG for 116–185 ft (36–56 m); 14 AWG for 186–295 ft (57–89 m); 12 AWG for 296–460 ft (90–140 m)
Nominal system voltage
120/240 V
Generator control wiring
Class 1 signaling circuit; interconnections may include N1, N2, T1 and leads 23 and 194
Utility service breaker voltage and frequency
240/480 VAC; 50/60 Hz
Transfer & Features
Automatic/Manual
Automatic
Features
Mountable, Water Resistant
Engine warmup delay
5-second factory setting; adjustable from 2 to 1,500 seconds by a qualified dealer with Evolution™ controls
Load transition type
Open transition
Neutral switching
Three-phase neutral connects to a neutral lug and is not switched