| Brand | Generac |
|---|---|
| MPN | RTSW400A3 |
| SKU | RTSW400A3 |
| Category | Automatic Transfer Switches |
| Maximum Amperage (A) | 400 |
|---|---|
| Maximum Wattage (W) | 96000 |
| Fused | Non-Fused |
| Automatic/Manual | Automatic |
| Maximum Amperage (A) | 400 |
|---|---|
| Maximum Wattage (W) | 96000 |
| Fused | Non-Fused |
| Generator control wiring classification | Class 1 signaling circuit |
| Power terminal torque | 375 in-lb (42.4 N·m) |
| Utility service breaker frequency | 50/60 Hz |
| Power terminal conductor range | (1) #4–600 MCM or (2) 1/0–250 MCM, Cu/Al |
| Auxiliary contact rating | 10 A at 125 or 250 V AC |
| Conductor-terminal torque | 375 in-lbs (42.4 Nm) |
| Power terminal construction | Solderless, screw-type terminal lugs |
| Smart A/C module contact rating | 24 VAC, 1.0 A maximum |
| Maximum tungsten load | 30 % of switch rating |
| Supply-circuit short-circuit suitability | Circuit capable of 22,000 rms symmetrical amperes at 240 VAC maximum |
| Power-conductor lug range | One conductor: #4–600 MCM Cu/Al; two conductors: 1/0–250 MCM Cu/Al |
| Short-circuit withstand rating | 22,000 A |
| Automatic/Manual | Automatic |
|---|---|
| Features | Mountable, On Indicator Light, Overload Protection, Water Resistant |
| Load-shed frequency thresholds | Less than 58 Hz for 3 seconds or less than 50 Hz for 0.5 second, for 60 Hz systems |
| Timing and sensing control location | Controller at the generator |
| Compatible load types | Motors, electric discharge lamps, tungsten filament, and electric heating equipment |
| Mounting orientation | Mount vertically to a rigid supporting structure |
| Neutral switching | Neutral connects to a neutral lug and is not switched |
| Generator-controller compatibility | Evolution™ or Nexus™ Controller |
| A/C load-shed contact behavior | Normally closed; opens during load-shed conditions |
| Height (in.) | 48 |
|---|---|
| Width (in.) | 21.8 |
| Length (in.) | 10 |
| Weight (lb.) | 140 |
| Finish | Electrostatically applied and baked powder paint |
| Enclosure material | Aluminum |