Skip to content

Generac XG Protector Series 80 kW Standby Generator

0 Reviews
SKU
XG08045ANAX

The Generac XG Protector Series XG08045ANAX is an automatic, liquid-cooled standby generator listed for commercial use, with 80 kW running output, 333 A amperage, and 120/240 VAC single-phase output. Its listed fuel options are natural gas and liquid propane; features also include Quiet-Test mode and Mobile Link connectivity.

  • 80 kW Running Output
  • 120/240 VAC Single-Phase Output
  • Natural Gas or Liquid Propane Fuel
  • 333 A Listed Amperage
  • 4.5 L Liquid-Cooled Engine
  • Automatic Voltage Regulation

The Generac XG Protector Series XG08045ANAX is an automatic, liquid-cooled standby generator listed for commercial use, with 80 kW running output, 333 A amperage, and 120/240 VAC single-phase output. Its listed fuel options are natural gas and liquid propane; features also include Quiet-Test mode and Mobile Link connectivity.

Product Overview

The Generac XG Protector Series XG08045ANAX is an automatic, liquid-cooled standby generator listed for commercial use, with 80 kW running output, 333 A amperage, and 120/240 VAC single-phase output. Its listed fuel options are natural gas and liquid propane; features also include Quiet-Test mode and Mobile Link connectivity.

  • 80 kW Running Output
  • 120/240 VAC Single-Phase Output
  • Natural Gas or Liquid Propane Fuel
  • 333 A Listed Amperage
  • 4.5 L Liquid-Cooled Engine
  • Automatic Voltage Regulation

Technical Specifications

Product information and specifications for the selected item.

SKU: XG08045ANAX

Product Information

BrandGenerac
MPNXG08045ANAX
SKUXG08045ANAX
UPC / GTIN696471107616
CategoryCommercial Standby Generators

Key Specs

Running Wattage80000 W
Amperage (A)333
Output Voltage120/240 VAC
Electrical Phases1
Fuel TypeLiquid Propane, Natural Gas
LP Power Capacity75000

Generator Output

Running Wattage80000 W
Amperage (A)333
Output Voltage120/240 VAC
Electrical Phases1
Rated frequency60 Hz
Voltage regulationDigital, ±1 %
Total harmonic distortion<5 %
1-phase circuit breaker rating400 A

Fuel Capacity

Fuel TypeLiquid Propane, Natural Gas
LP Power Capacity75000
Fuel supply pressure requirementsLP vapor: 7–14 (1.74–3.48); natural gas: 3.5–14 (0.87–3.48) in H2O (kPa)
Fuel consumption at 100% loadLP: 14.2 US gph (53.8 L/h); natural gas: 1,270 CFH (36.0 mÂł/h)
Recommended minimum LP tank size250 (946) US gal (L)

Engine & Cooling

Engine BrandGenerac
Cooling TypeLiquid Cooled
RPM1800 rpm
Engine configuration4.5 L inline 4-cylinder, turbocharged and aftercooled
Temperature derate8.3% per 10 °F above 86 °F (7.5% per 5 °C above 30 °C)
Maximum ambient air temperature122 (50) °F (°C)
Underbody and airflow installation requirementsEnclose the generator bottom to prevent pest intrusion and discharge-air recirculation or improper cooling airflow; allow free flow of intake, discharge, and exhaust air
Coolant specification and capacity50/50 coolant (50% ethylene glycol); capacity 2.9 US gal (11 L)
Post-break-in oil serviceAfter the initial 25-hour break-in, replace factory-fill conventional 5W-20 oil with Generac proprietary 5W-20 Full Synthetic oil
Altitude derate3% per 1,000 ft above 3,000 ft (1% per 100 m above 915 m)

Features & Connections

Generator FeaturesAutomatic Voltage Regulation, Hour Meter, Low Oil Alert/Shutdown
FeaturesApproved for Commercial Use, EPA Compliant, Made in America
Approved for Commercial UseYes
Battery requirementsRecommended: flooded lead-acid Group 27, 600 CCA minimum; maximum allowable: flooded lead-acid Group 31, 750 CCA minimum
Listings and emissions certificationUL 2200 listed; EPA emissions certified
Wind speed rating145 mph (233 km/h), ASCE 7-16 Exposure B; requires a correctly prepared concrete pad and anchoring system
Fuel line connection1-1/4 in. NPT female tee through the baseframe opening
Enclosure, baseframe, exhaust materials and finishAluminum enclosure; electro-galvanized baseframe components; stainless-steel exhaust system; Metro Gray finish
Sound levels at 23 ft (7 m)55 at exercise speed; 64 at operating speed with no load dB(A)
Battery charging system145 A charge alternator; 5 A battery charger

Dimensions & Weight

Height (in.)51.2
Width (in.)33.6
Length (in.)104.8
Weight (lb.)1781
Mounting bolt or stud diameter1/2 in.
Conduit stub-up height requirement38–140 (1.5–5.5) mm (in.)
Recommended concrete pad sizeMinimum recommended pad: 45.6 Ă— 116.8 in. (1159 Ă— 2966 mm), with a 6-in. offset from the generator footprint

Product Documents

  • Installation Drawing — Install G4.5L Turbo XG60/80 kW CPL (A0009887867, Rev. A) Drawing photometric Open / download file
  • Emissions Warranty Statement (Spark-Ignition Engine Powered Generators) (A0006376253, Rev. C) Warranty Open / download file
  • Generac Power Systems 5 Year (5M) Limited Warranty for Residential and Commercial Standby Generators Warranty Open / download file
  • Owner's Manual — Spark-Ignited Stationary Generators, Models XG03245–XG08045 (A0005536684) Manual Open / download file
  • XG Protector Series Standby Generators — Liquid-Cooled Gaseous Engine (A0005286945, Rev. D) Spec sheet Open / download file

Your cart