Skip to content
Global Power Products

Global Power Products New Era NE-5000 400A Surface-Mount kWh Submeter

0 Reviews
SKU
NE-5000-400

The Global Power Products New Era NE-5000 is a surface-mount kWh submeter for 400 A split-core CT monitoring, with a 120–240 VAC supply, Class 0.2 accuracy, True-RMS measurement, NEMA 4X enclosure, and BACnet MS/TP, Ethernet, KYZ pulse, and RS485 connection methods.

  • 400 A Split-Core CT
  • Single- and Three-Phase Support
  • Class 0.2 True-RMS Measurement
  • BACnet MS/TP, Ethernet, KYZ, RS485
  • 120–240 VAC Supply
  • Surface-Mount NEMA 4X Enclosure

Product Overview

The Global Power Products New Era NE-5000 is a surface-mount kWh submeter for 400 A split-core CT monitoring, with a 120–240 VAC supply, Class 0.2 accuracy, True-RMS measurement, NEMA 4X enclosure, and BACnet MS/TP, Ethernet, KYZ pulse, and RS485 connection methods.

Technical Specifications

Product information and specifications for the selected item.

SKU: NE-5000-400

Product Information

BrandGlobal Power Products
MPNNE-5000-400
SKUNE-5000-400
CategoryMetering Equipment

Key Specs

Monitoring Primary Rated Current400 A
Monitoring Rated Power480 VAC
Monitoring Supply Voltage120-240 VAC
Monitoring Accuracy ClassClass 0.2
NEMA Enclosure RatingNEMA 4X

Monitoring & Electrical

Monitoring Primary Rated Current400 A
Monitoring Rated Power480 VAC
Monitoring Supply Voltage120-240 VAC
CT multiplier4, programmed internally
Operating frequency range47 to 63 Hz
Power circuit burden0.24 max (phases B and C) VA
Test-mode readingsSequential phase voltage, current, and instantaneous power readings
Current circuit burden1 max (phases A, B, C) VA
Measurement methodTrue RMS
Voltage circuit burden8.6 max (phase A) VA

Configuration & Interface

ComponentEnergy Meter
Monitoring TypeCurrent, Energy Consumption, Frequency, Power, Total Energy, Voltage
Monitoring Connection MethodBacnet MSTP, Ethernet, KYZ Pulse, RS485
Monitoring Interface1P + N, 3P, 3P + N, LCD
Monitoring Switching Output1 Pulse
Number of Meters1
CT installation locationIncoming lines or individual breakers
Conduit entry3/4 bottom entry in
Terminal-block conductor size18–14 copper AWG
CT polarity orientationPolarity dot faces the line or supply side
Supported service configurations3-phase 4-wire Wye/Delta; 3-phase 3-wire Delta; 1-phase 2- or 3-wire
Terminal-block tightening torque6 lb-in

Ratings & Approvals

NEMA Enclosure RatingNEMA 4X
Monitoring Accuracy ClassClass 0.2
Monitoring ApprovalANSI C12.20, ANSI C37.90.1, UL
Operating temperature range-40 to +85 °C
Maximum altitude2000 maximum
Measurement categoryCategory III
Relative humidity range0 to 95, non-condensing %
Pollution degree2
Installation overvoltage categoryCategory III
Insulation and surge protection standardANSI / IEEE C37.90.1 - 1989
Metering standardANSI C12.20

Dimensions & Weight

Mounting tabs3 tabs on the back of the enclosure
Minimum mounting height18 minimum above floor
Maximum CT panel wiring-space occupancyMust not exceed 75 in any cross-sectional area %

Product Documents

  • NEW ERA METER Installation & Operation Guide (NE Manual – 06-04-19) Installation manual Open / download file
  • Smart Revenue-Grade Surface Mount Meter — Specifications (2024) Spec sheet Open / download file