The Greenlee 860-1-1/2 PVC heating blanket provides controlled, even heating for bending PVC conduit. It has a stated 1/2–1-1/2 in. conduit capacity, operates at 120 VAC and 200 W, and is compatible with Schedule 20–80 PVC conduit and EB/DB duct.
1/2–1-1/2 in. conduit capacity
Schedule 20–80 and EB/DB compatibility
120 VAC input, 200 W
CSA and UL certified
Hook-and-loop securing strap
Built-in stiffeners
The Greenlee 860-1-1/2 PVC heating blanket provides controlled, even heating for bending PVC conduit. It has a stated 1/2–1-1/2 in. conduit capacity, operates at 120 VAC and 200 W, and is compatible with Schedule 20–80 PVC conduit and EB/DB duct.
The Greenlee 860-1-1/2 PVC heating blanket provides controlled, even heating for bending PVC conduit. It has a stated 1/2–1-1/2 in. conduit capacity, operates at 120 VAC and 200 W, and is compatible with Schedule 20–80 PVC conduit and EB/DB duct.
1/2–1-1/2 in. conduit capacity
Schedule 20–80 and EB/DB compatibility
120 VAC input, 200 W
CSA and UL certified
Hook-and-loop securing strap
Built-in stiffeners
Technical Specifications
Product information and specifications for the selected item.
SKU: 860-1-1/2
Product Information
Brand
Greenlee
MPN
860-1-1/2
SKU
860-1-1/2
UPC / GTIN
0783310314868
Category
Safety Supplies
Key Specs
Certifications and Listings
CSA Certified, UL Certified
Bundle/Single
Single Product
Safety & Compliance
Certifications and Listings
CSA Certified, UL Certified
Blanket securing method
Wrap around PVC and secure with a hook and loop strap
Wattage
200 W
Maximum bend angle for 3/4-in conduit
90 °
Maximum bend angle for 1/2-in conduit
90 °
Recommended extension-cord wire gauge
18 AWG for both under 100 ft and 100–150 ft extension cords
Input voltage
120 VAC
Rated power
200 W
Cord and temperature control
Heavy-duty cord and thermostat
Conduit compatibility
Schedule 20–80 PVC conduit and EB/DB duct
Power source voltage
120 VAC
Approximate warm-up time for 1/2-in conduit at 70°F / 21°C ambient
Sch. 40: 3-4; Sch. 80: 4-5 min
Blanket construction
Built-in stiffeners help keep the blanket tight to the PVC surface
Heating characteristic
Controlled, even heating for uniform bending
Approximate warm-up time for 3/4-in conduit at 70°F / 21°C ambient
Sch. 40: 4-5; Sch. 80: 5-6 min
Heating temperature
Over 300 °F
Compatible conduit and duct
Schedule 20 through Schedule 80 PVC conduit and EB and DB duct for bending
Approximate warm-up time for 1-1/4-in conduit at 70°F / 21°C ambient
Sch. 40: 6-7; Sch. 80: 7-8 min
Warm-up time variability
Actual times may vary based on ambient temperature, wind conditions outdoors, and line voltage
Maximum bend angle for 1-1/4-in conduit
45 °
Ambient operating temperature range
20–100 °F
Material
Silicon Rubber compound
Package & Appearance
Bundle/Single
Single Product
Dimensions & Weight
Width (in.)
8.25
Length (in.)
13
Weight (lb.)
1.7
Recommended minimum centerline bend radius for 3/4-in conduit
5 in.
Recommended minimum centerline bend radius for 1/2-in conduit
4 in.
Recommended minimum centerline bend radius for 1-1/4-in conduit