Skip to content

ILSCO SK-2/0 CU Tin-Plated Copper Split-Bolt Connector

0 Reviews
SKU
SK-2/0 CU

The ILSCO SK-2/0 CU is a tin-plated copper split-bolt clamp connector for equal main-and-tap conductors. Its listed ranges are 2/0–6 AWG stranded, 2/0–5 AWG solid, and 1/0–6 ACSR; it is UL 486A/B and CSA listed with a 35 kV voltage rating.

  • Equal Main-and-Tap Wire Ranges
  • Tin-Plated Copper Construction
  • 35 kV Voltage Rating
  • UL 486A/B and CSA Listing
  • 90°C Temperature Rating
  • 385 in-lb Tightening Torque

The ILSCO SK-2/0 CU is a tin-plated copper split-bolt clamp connector for equal main-and-tap conductors. Its listed ranges are 2/0–6 AWG stranded, 2/0–5 AWG solid, and 1/0–6 ACSR; it is UL 486A/B and CSA listed with a 35 kV voltage rating.

Product Overview

The ILSCO SK-2/0 CU is a tin-plated copper split-bolt clamp connector for equal main-and-tap conductors. Its listed ranges are 2/0–6 AWG stranded, 2/0–5 AWG solid, and 1/0–6 ACSR; it is UL 486A/B and CSA listed with a 35 kV voltage rating.

  • Equal Main-and-Tap Wire Ranges
  • Tin-Plated Copper Construction
  • 35 kV Voltage Rating
  • UL 486A/B and CSA Listing
  • 90°C Temperature Rating
  • 385 in-lb Tightening Torque

Technical Specifications

Product information and specifications for the selected item.

SKU: SK-2/0 CU

Product Information

BrandILSCO
MPNSK-2/0 CU
SKUSK-2/0 CU
CategoryTerminals, Splices & Connectors

Key Specs

Wire Connector TypeClamp
Minimum Wire Gauge6
Color FamilySilver
Length (in.)1.82

Connector & Wire

Wire Connector TypeClamp
Minimum Wire Gauge6
Main drive size13/16
Wire stripping requirementsOn insulated wires, strip enough for clamp contact and avoid insulation overlap and nicking strands; strip immediately before installation on insulated 90°C maximum-rated wire in NEC applications.
Conductor surface preparationClean the conductor with a wire brush or abrasive cloth; apply antioxidant to stripped ends and work it into the strands.
Recommended tightening torque385 in-lb
Connector materialCopper
Direct burialNo
RUS listedYes
Voltage rating35 kV
Equal run-and-tap ACSR range1/0 ACSR - 6 ACSR
Listed conductor pairingsCopper-to-copper, Copperweld-to-Copperweld, and copper-to-Copperweld pairings
Main drive typeExternal Hex
Temperature rating90 °C
NEMA codeS-588-4
Conductor typeStranded
Tap installation and spacer positioningFor a tap, remove the nut/pressure bar and spacer, position the connector on the main wire, reinstall the spacer and hardware, and insert the tap to full clamp contact. Clamp the spacer between the wires with its radius side facing the nut/pressure bar.
UL/CULUS specificationUL 486A/B Listed
Equal run-and-tap solid conductor range2/0 Sol - 5 Sol
CSA standardC22.2 No. 65
Splice installationFor a splice, insert wires from opposite sides to full clamp contact, hand-tighten, then torque to the specified value.
Installation torque385 in-lb
California Proposition 65 warningWarning: Cancer and Reproductive Harm
Dual ratedNo
Minimum tap with maximum run10 Sol

Color & Finish

Color FamilySilver
Connector finishTin

Dimensions & Weight

Height (in.)1
Width (in.)1.15
Length (in.)1.82
Weight (lb.)0.217

Product Documents

Your cart

0 products 0 units

Your cart is empty.

Add products as you browse, then review them here.