The Intermatic GM40AVE-R is a digital electronic time switch with 24-hour and 7-day scheduling, 14 setpoints, and automatic 120–277 VAC voltage detection. It has DPDT contacts (2 NO/2 NC), 40 A NO/30 A NC resistive ratings, a Type 3R plastic indoor/outdoor enclosure, manual override, and up to 2,500 hours of Ni-MH battery backup.
The Intermatic GM40AVE-R is a digital electronic time switch with 24-hour and 7-day scheduling, 14 setpoints, and automatic 120–277 VAC voltage detection. It has DPDT contacts (2 NO/2 NC), 40 A NO/30 A NC resistive ratings, a Type 3R plastic indoor/outdoor enclosure, manual override, and up to 2,500 hours of Ni-MH battery backup.
The Intermatic GM40AVE-R is a digital electronic time switch with 24-hour and 7-day scheduling, 14 setpoints, and automatic 120–277 VAC voltage detection. It has DPDT contacts (2 NO/2 NC), 40 A NO/30 A NC resistive ratings, a Type 3R plastic indoor/outdoor enclosure, manual override, and up to 2,500 hours of Ni-MH battery backup.
Product information and specifications for the selected item.
| Brand | Intermatic |
|---|---|
| MPN | GM40AVE-R |
| SKU | GM40AVE-R |
| Category | Photocells & Timers |
| Voltage (V) | 120/208/240/277 V |
|---|---|
| Timer Type | Digital |
| Voltage (V) | 120/208/240/277 V |
|---|---|
| Resistive rating, NC contacts | 30 A, 120-277 VAC |
| Supported load phases | Controls one or two single-phase loads; not for direct control of three-phase loads. |
| Electronic ballast rating, NO contacts | 30 A at 120 VAC; 20 A at 277 VAC |
| Voltage detection method | Automatically detects input voltage without a DIP switch or selector pins. |
| Maximum wire size | #8 AWG |
| Tungsten incandescent rating, NO contacts | 15 A at 120 VAC |
| Motor rating, NC contacts | 1 HP, 12 FLA, 30 LRA @ 120 VAC, 50/60 Hz; 2 HP, 10 FLA, 30 LRA @ 240 VAC, 50/60 Hz |
| Pilot duty rating | 300 VA at 120-240 VAC |
| Tungsten incandescent rating, NC contacts | 2 A at 120 VAC |
| Relay power requirement | AC voltage must be present at L1 and L2/N for the relays to operate and the status indicator to change from ON to OFF. |
| Electronic ballast rating, NC contacts | 10 A at 277 VAC |
| Conductor requirements | Copper conductors only; minimum #8 AWG for 40 A loads or #10 AWG for 30 A loads; minimum 90°C (194°F). |
| Timer Type | Digital |
|---|---|
| Outdoor Lighting Features | Timer |
| Enclosure retrofit compatibility | Can be retrofitted into other Intermatic enclosure types. |
| Minimum ON/OFF interval | 1 min |
| Daylight-saving adjustment | Manual |
| Features | Flexible, Indicator Light, Programmable |
|---|---|
| Eco Friendly | Energy Efficient |
| Finger-safe terminals | Yes |
| Wiring connection type | Screw box lug terminals |
| Battery chemistry and service type | Ni-MH chemistry; non-replaceable battery. |
| UL listing | cULus; UL file #E10694 |
| Operating temperature range | 5°F-131°F (-15°C-55°C) |
| RoHS certification | Yes |
| Outdoor/wet-location conduit hubs | For outdoor or wet (rain-tight) locations, use conduit hubs compliant with UL514B. |
| Operating humidity | 10-95% RH, non-condensing |
| Conduit grounding requirement | The enclosure does not provide grounding between conduit connections; metallic conduit requires grounding-type bushings and a jumper wire per NEC. |
| Color Family | Gray |
|---|
| Height (in.) | 8.875 |
|---|---|
| Width (in.) | 6.61 |
| Length (in.) | 3 |
| Weight (lb.) | 1.83 |
Added to cart