Intermatic T103 24-Hour Mechanical Time Switch, 120VAC, DPST
0 Reviews
SKU
T103
The Intermatic T103 is a 24-hour mechanical time switch with DPST switching and a 40 A rating. Its 120 VAC, 60 Hz clock motor supports one-hour minimum on/off intervals and up to 12 on/off operations per day. The unit has a Type 1 indoor metal enclosure.
40 A DPST Switching
120 VAC, 60 Hz Clock Motor
24-Hour Mechanical Timer
Up to 12 Daily Operations
One-Hour Minimum Interval
Type 1 Indoor Metal Enclosure
The Intermatic T103 is a 24-hour mechanical time switch with DPST switching and a 40 A rating. Its 120 VAC, 60 Hz clock motor supports one-hour minimum on/off intervals and up to 12 on/off operations per day. The unit has a Type 1 indoor metal enclosure.
The Intermatic T103 is a 24-hour mechanical time switch with DPST switching and a 40 A rating. Its 120 VAC, 60 Hz clock motor supports one-hour minimum on/off intervals and up to 12 on/off operations per day. The unit has a Type 1 indoor metal enclosure.
40 A DPST Switching
120 VAC, 60 Hz Clock Motor
24-Hour Mechanical Timer
Up to 12 Daily Operations
One-Hour Minimum Interval
Type 1 Indoor Metal Enclosure
Technical Specifications
Product information and specifications for the selected item.
SKU: T103
Product Information
Brand
Intermatic
MPN
T103
SKU
T103
UPC / GTIN
078275000049
Category
Photocells & Timers
Key Specs
Voltage (V)
120 V
Amperage (A)
40
Timer Type
Mechanical
Electrical Ratings
Voltage (V)
120 V
Amperage (A)
40
Frequency
60 Hz
Minimum wire insulation temperature
90 minimum °C
Conductor requirements
Copper conductors only, rated at least 90°C; solid or stranded conductors; two wires of the same size and type may be used.
Operating temperature
-40 °F to 130 °F / -40 °C to 54 °C
Maximum wire size
#8 AWG
Wire-end stripping length
1/2 in
Minimum wire size
#14 AWG
Wire size range
#14 minimum; #8 maximum AWG
Terminal wire allowance
Two wires of the same size and type may be used
Terminal screw torque
2–18 in-lbs
Conductor material and type
Solid or stranded copper conductors only
Maximum power consumption
3 W
Control & Timing
Timer Type
Mechanical
Outdoor Lighting Features
Timer
Power-failure recovery
Reset the clock dial to the proper time after a power failure.
Clock-dial handling
Rotate the timer dial clockwise only; do not move the clock hands, which can damage the timer.
Minimum ON/OFF time
1 hour
Time setting
Pull the clock dial outward and turn either direction to set the time.
Features & Included
Features
On/Off Switch, Programmable
Eco Friendly
Energy Efficient
Enclosure classification
Indoor Type 1 metal
Terminal insulator requirement
Reinstall the plastic terminal insulator before powering on