The Kidde HD135F is a 120 V AC hardwired heat alarm with a 135°F heat response and 9 V battery backup. It has a test button, an audible alarm level of 85 dB at 10 ft (3 m), and supports interconnection with up to 24 Kidde devices.
135°F Heat Response
120 V AC Hardwired Power
9 V Battery Backup
Interconnection With Up to 24 Kidde Devices
UL-Recommended Coverage: 2,500 sq ft
UL Listed
The Kidde HD135F is a 120 V AC hardwired heat alarm with a 135°F heat response and 9 V battery backup. It has a test button, an audible alarm level of 85 dB at 10 ft (3 m), and supports interconnection with up to 24 Kidde devices.
The Kidde HD135F is a 120 V AC hardwired heat alarm with a 135°F heat response and 9 V battery backup. It has a test button, an audible alarm level of 85 dB at 10 ft (3 m), and supports interconnection with up to 24 Kidde devices.
135°F Heat Response
120 V AC Hardwired Power
9 V Battery Backup
Interconnection With Up to 24 Kidde Devices
UL-Recommended Coverage: 2,500 sq ft
UL Listed
Technical Specifications
Product information and specifications for the selected item.
SKU: HD135F
Product Information
Brand
Kidde
MPN
HD135F
SKU
HD135F
UPC / GTIN
025417841350
Category
Safety Supplies
Key Specs
Safety Features
Other
Certifications and Listings
UL Listed
Bundle/Single
Bundle
Safety & Compliance
Safety Features
Other
Certifications and Listings
UL Listed
Side-wall placement
Inside wall; top edge 4 in (10 cm) minimum to 12 in (30.5 cm) maximum below ceiling
Replacement battery chemistries
Carbon-zinc; alkaline and lithium types may also be used 9 V
UL-recommended coverage
2,500 sq ft
Maximum interconnectable devices
Up to 24 Kidde devices
Cover construction
Sealed unit; cover is not removable
Required AC circuit
120 V AC, single-phase; non-switchable; not GFCI-protected
Inverter compatibility
Not operable from square-wave or modified-square-wave inverter power
Junction-box compatibility
Standard single-gang electrical box, up to a 4-in octagon junction box
Compatible device family
Kidde/Lifesaver smoke alarms; verify model compatibility
UL-recommended spacing
50 ft
Maximum distance from wall
25 ft
Recommended replacement interval from date code
10 years
Expected fresh-battery life
1 year under normal operating conditions
Operating humidity range
5–95 % RH, non-condensing
Maximum current draw
80 maximum per alarm
Operating temperature range
-20 to +100 °F
Sloped-ceiling placement
At or within 3 ft (0.9 m) of the highest point, measured horizontally
Audible alarm level
85 dB at 3 m (10 ft)
Interconnect wiring route
Same raceway or cable as AC power wiring
NFPA interconnect limit
12 smoke or smoke/CO combination alarms and/or 18 total alarms
Electrical connector
Plug-in connector
Maximum interconnect wire run
1,000 ft
Interconnect wiring resistance limit
10 maximum ohms
Interconnected power requirement
All interconnected units must be powered from one circuit