586-554-2000
Mon–Fri 6:30am–5pm · Sat 8am–3pm
586-554-2000
Mon–Fri 6:30am–5pm
The KOHLER 26RCA-QS2 is an air-cooled commercial standby generator with 120/208 VAC three-phase output. It runs on natural gas or LPG, with stated fuel-specific output of 21 kW on natural gas and 22 kW on LPG, and uses a 999 cm³ V-twin engine in an aluminum enclosure.
The KOHLER 26RCA-QS2 is an air-cooled commercial standby generator with 120/208 VAC three-phase output. It runs on natural gas or LPG, with stated fuel-specific output of 21 kW on natural gas and 22 kW on LPG, and uses a 999 cm³ V-twin engine in an aluminum enclosure.
The KOHLER 26RCA-QS2 is an air-cooled commercial standby generator with 120/208 VAC three-phase output. It runs on natural gas or LPG, with stated fuel-specific output of 21 kW on natural gas and 22 kW on LPG, and uses a 999 cm³ V-twin engine in an aluminum enclosure.
Product information and specifications for the selected item.
| Brand | Kohler |
|---|---|
| MPN | 26RCA-QS2 |
| SKU | 26RCA-QS2 |
| Category | Commercial Standby Generators |
| Running Wattage | 22000 W |
|---|---|
| Amperage (A) | 77 |
| Output Voltage | 120/208 VAC |
| Electrical Phases | 3 |
| Fuel Type | Dual-Fuel (LP/NG) |
| LP Power Capacity | 22000 |
| Running Wattage | 22000 W |
|---|---|
| Amperage (A) | 77 |
| Output Voltage | 120/208 VAC |
| Electrical Phases | 3 |
| One-step load acceptance | 100 % of rating |
| Winding material and treatment | Copper windings; vacuum-impregnated with epoxy varnish |
| Standby rating conditions | Standby rating applies to reliable-utility installations; variable loads average an 80% load factor during the outage; no overload capacity specified |
| Frequency regulation | ±0.5 steady-state % |
| Total harmonic distortion | Less than 5 from no-load to full-load with a linear load % |
| Alternator model and lead count | 2F8; 4 leads |
| Altitude and temperature derating | Altitude: derate 4% per 305 m (1,000 ft.) above 153 m (500 ft.); temperature: derate 2% per 5.5°C (10°F) above 16°C (60°F) |
| Insulation class and temperature rise | NEMA MG1-1.66, Class H; 130°C temperature rise at standby |
| Fuel Type | Dual-Fuel (LP/NG) |
|---|---|
| LP Power Capacity | 22000 |
| NG Power Capacity | 21000 |
| Fuel consumption at full load, 60 Hz | At 100% load, natural gas: 8.2 m³/hr (290 cfh); LPG: 3.6 m³/hr (129 cfh). m³/hr (cfh) |
| Fuel supply pressure | Natural gas: 3.5–11; LPG: 7–11 in. H2O |
| Fuel consumption at 50% load | Natural gas: 180; LPG: 85 at 50% load cfh |
| Fuel composition limits | Natural gas: methane ≥90 vol%, ethane ≤4.0%, propane ≤1.0%, propene ≤0.1%, C4+ ≤0.3%, minimum LHV 33.2 MJ/m³ (890 Btu/ft³). LPG: propane ≥85 vol%, propene ≤5.0%, C4+ ≤2.5%, minimum LHV 84.2 MJ/m³ (2260 Btu/ft³). Sulfur maximum 25 ppm by mass. |
| Fuel inlet connection | 3/4 NPT female |
| Minimum gas pipe size by line length | NG 1 in. / LPG 3/4 in. at 25 ft; NG 1-1/4 in. / LPG 1 in. at 50–150 ft; NG 1-1/2 in. / LPG 1-1/4 in. at 200 ft in. NPT |
| Engine Brand | Kohler |
|---|---|
| Cooling Type | Air Cooled |
| RPM | 3600 rpm |
| Engine configuration and displacement | CH1006, four-cycle V-2; displacement 999 cm³ (61 cu. in.) |
| Generator Features | Automatic Voltage Regulation, Hour Meter, Low Oil Alert/Shutdown |
|---|---|
| Features | Approved for Commercial Use, CARB approved, EPA Compliant |
| Approved for Commercial Use | Yes |
| Standard warranty | 5-year/2,000-hour limited standby warranty; covers parts, labor, and travel |
| Wind rating | 181 mph |
| Starting battery requirement | 12 VDC negative-ground starting battery; Group 51; minimum 500 CCA at −18°C (0°F) |
| Listings and acceptance | cULus listed; accepted by the Massachusetts Board of Registration of Plumbers and Gas Fitters |
| Standard enclosure finish | Cashmere (standard) |
| Enclosure foam specification | Sound-deadening, flame-retardant foam; UL 94 class HF-1 |
| Sound level | 56 during engine exercise; 67 during full-speed diagnostics and normal operation; measured at 23 ft (7 m) dB(A) |
| Installation environment | Outdoor installation only |
| Height (in.) | 32.3 |
|---|---|
| Width (in.) | 26 |
| Length (in.) | 47 |
| Combustible-material clearance guideline | 18-inch NFPA guideline to combustible materials; verify required structure spacing with state and local codes in. |
Added to cart