Skip to content
KOHLER

KOHLER 48RCLC-QS6 48kW Liquid-Cooled Standby Generator, 120/208VAC 3-Phase, OnCue Plus

0 Reviews
SKU
48RCLC-QS6

The KOHLER 48RCLC-QS6 is a commercial liquid-cooled standby generator rated at 48 kW on natural gas and 50 kW on LP, with 120/208 VAC three-phase output, a 175 A three-pole breaker, and an RDC2 controller with OnCue Plus.

  • 48 kW NG / 50 kW LP Output
  • 120/208 VAC Three-Phase, 60 Hz
  • 175 A Three-Pole Breaker
  • Liquid-Cooled 6.2 L Engine
  • RDC2 Controller and OnCue Plus
  • cUL/UL 2200 Listed; CSA Certified

Product Overview

The KOHLER 48RCLC-QS6 is a commercial liquid-cooled standby generator rated at 48 kW on natural gas and 50 kW on LP, with 120/208 VAC three-phase output, a 175 A three-pole breaker, and an RDC2 controller with OnCue Plus.

Technical Specifications

Product information and specifications for the selected item.

SKU: 48RCLC-QS6

Product Information

BrandKOHLER
MPN48RCLC-QS6
SKU48RCLC-QS6
CategoryCommercial Standby Generators

Key Specs

Running Wattage48000 W
Amperage (A)167
Output Voltage120/208 VAC
Electrical Phases3
Fuel TypeDual-Fuel (LP/NG)
LP Power Capacity50

Generator Output

Running Wattage48000 W
Amperage (A)167
Output Voltage120/208 VAC
Electrical Phases3
Unbalanced load capability100% of rated standby current
Three-phase power factor0.8 power factor
One-step load acceptance100% of rating accepted in one step
Alternator voltage regulation±1.0% RMS, no-load to full-load
Sustained short-circuit capabilityUp to 300% of rated current for up to 10 seconds
Total harmonic distortionLess than 4% from no load to full load with a linear load

Fuel Capacity

Fuel TypeDual-Fuel (LP/NG)
LP Power Capacity50
NG Power Capacity48
Natural-gas consumption at full load24.8 (875) at 100% load mÂł/hr (cfh)
Fuel supply pressure1.2–2.7 kPa (5–11 in. H₂O) for natural gas and LPG vapor
LPG consumption at full load8.9 (315) at 100% load; 8.7 mÂł/hr (cfh); gal/hr

Engine & Cooling

Engine BrandKohler
Cooling TypeLiquid Cooled
RPM1800 rpm
Oil capacity with filter7.1 (7.5) L (qt.)
Engine displacement6.2 (378) L (cu. in.)
Radiator-system ambient temperature45 (113) °C (°F)
Emissions certification60 Hz engine certified to EPA NSPS for stationary spark-ignited emissions
Recommended starting-battery ratingOne battery, 630 CCA at 0°F

Features & Connections

Generator FeaturesAutomatic Voltage Regulation, Hour Meter, Low Oil Alert/Shutdown
Plug Type(1) NEMA 5-20R - GFCI
FeaturesApproved for Commercial Use, EPA Compliant
Approved for Commercial UseYes
Enclosure constructionSkid-mounted aluminum construction with two removable access panels
Safety certificationscUL/UL 2200 listed; CSA certified
WarrantyPremium limited warranty: 5 years / 2,000 hours; covers all systems and components
Enclosure insulationAcoustic insulation meets UL 94 HF1 flammability classification and repels moisture absorption
Fuel inlet connection1 in. NPT
Enclosure finishCashmere powder-baked; scratch- and corrosion-resistant

Dimensions & Weight

Height (in.)46.5
Width (in.)32.9
Length (in.)89.8
Weight (lb.)1690
Exhaust-to-opening clearanceAt least 5 ft from the generator exhaust end
Installation location and surfaceMust be installed outdoors on a non-combustible surface
Minimum structure clearance18 minimum; actual distance may vary with state and local codes in.
Concrete pad requirement4 in. thick; extends 6 in. beyond the genset on all sides