Skip to content
Kohler

Kohler 60RCLB-QS6 60kW 120/208VAC Three-Phase Standby Generator

0 Reviews
SKU
60RCLB-QS6

The Kohler 60RCLB-QS6 is an automatic, liquid-cooled 60 kW commercial standby generator with 120/208 VAC three-phase output and LP or natural gas fuel. It is specified at 209 A with a 225 A three-pole breaker and uses a 6.2 L naturally aspirated V-8 engine.

  • 60 kW Standby Output
  • 120/208 VAC Three-Phase Output
  • LP and Natural Gas Fuel
  • 209 A Rated Output
  • 225 A Three-Pole Breaker
  • RDC2 Controller

Product Overview

The Kohler 60RCLB-QS6 is an automatic, liquid-cooled 60 kW commercial standby generator with 120/208 VAC three-phase output and LP or natural gas fuel. It is specified at 209 A with a 225 A three-pole breaker and uses a 6.2 L naturally aspirated V-8 engine.

Technical Specifications

Product information and specifications for the selected item.

SKU: 60RCLB-QS6

Product Information

BrandKohler
MPN60RCLB-QS6
SKU60RCLB-QS6
CategoryCommercial Standby Generators

Key Specs

Running Wattage60000 W
Amperage (A)209
Output Voltage120/208 VAC
Electrical Phases3
Fuel TypeDual-Fuel (LP/NG)
LP Power Capacity60

Generator Output

Running Wattage60000 W
Amperage (A)209
Output Voltage120/208 VAC
Electrical Phases3
Total harmonic distortionLess than 3.5% from no-load to full-load with a linear load
Rated power factor0.8
Frequency and output connection60 Hz; Wye, 4-wire
Alternator insulation classClass H
Alternator temperature rise130°C at standby
Sustained short-circuit capabilityUp to 300% of rated current for up to 10 seconds
Voltage regulation±1.0% RMS, no-load to full-load

Fuel Capacity

Fuel TypeDual-Fuel (LP/NG)
LP Power Capacity60
NG Power Capacity60
Fuel supply pressureNatural gas and LPG vapor: 1.2–2.7 kPa (5–11 in. H₂O) kPa (in. H₂O)
Natural gas consumption at 100% load28.7 mÂł/h (1013 cfh) mÂł/h (cfh)
Fuel supply inlet1 in. NPT
LP gas consumption at 100% load10.1 mÂł/h (357 cfh; 9.8 gal/h) mÂł/h (cfh); gal/h

Engine & Cooling

Engine BrandKohler
Cooling TypeLiquid Cooled
RPM1800 rpm
Exhaust specificationsDry manifold; maximum back pressure 10.2 kPa (3.0 in. Hg); 76 mm (3.0 in) OD outlet
Engine model and typeKG6208, 6.2 L, naturally aspirated
Engine displacement6.2 L (cu. in. 378)
Starting battery requirementOne BCI group 24, 12 V battery; minimum 630 CCA at 0°F
Specified radiator-system ambient temperature45°C (113°F) °C (°F)
Lubrication system and capacityFull-pressure system; 7.1 L (7.5 qt) oil-pan capacity with filter L (qt)

Features & Connections

Generator FeaturesAutomatic Voltage Regulation, Hour Meter, Low Oil Alert/Shutdown
Plug Type(1) NEMA 5-20R - GFCI
FeaturesApproved for Commercial Use, EPA Compliant
Approved for Commercial UseYes
Enclosure finishCashmere powder-baked finish; scratch- and corrosion-resistant
Enclosure insulationUL 94 HF1 flammability classification; repels moisture absorption
Safety certificationsUL; CSA
Enclosure constructionSkid-mounted aluminum construction with two removable access panels

Dimensions & Weight

Height (in.)46.5
Width (in.)32.9
Length (in.)89.8
Weight (lb.)1900
Exhaust-to-opening clearanceAt least 5 ft from the exhaust end to the nearest window, vent, door, or similar opening
Minimum structure clearanceMinimum 18 in. from structure per NFPA 37; actual distance may vary by state and local code
Mounting pad requirement4-in.-thick concrete pad extending 6 in. beyond the generator set on all sides