The KOHLER RXT-JFTC-0200A-QS4 is an automatic 200 A, 3-pole, 4-wire transfer switch for KOHLER generators using RDC2 or DC2 controllers. Its aluminum NEMA 3R enclosure is specified for indoor or outdoor installation.

  • 200 A Maximum Amperage
  • 3-Pole, 4-Wire Configuration
  • Automatic Transfer Operation
  • KOHLER RDC2/DC2 Compatibility
  • Aluminum NEMA 3R Enclosure
  • UL Listed

Product Overview

The KOHLER RXT-JFTC-0200A-QS4 is an automatic 200 A, 3-pole, 4-wire transfer switch for KOHLER generators using RDC2 or DC2 controllers. Its aluminum NEMA 3R enclosure is specified for indoor or outdoor installation.

Technical Specifications

Product information and specifications for the selected item.

SKU: RXT-JFTC-0200A-QS4

Product Information

BrandKOHLER
MPNRXT-JFTC-0200A-QS4
SKURXT-JFTC-0200A-QS4
CategoryAutomatic Transfer Switches

Key Specs

Maximum Amperage (A)200
Automatic/ManualAutomatic
Certifications and ListingsUL Listed

Electrical Ratings

Maximum Amperage (A)200
Frequency60 Hz
External power terminal typeAL/CU solderless screw-type
Auxiliary contact rating15 A at 250 VAC; standard
Contactor/neutral terminal tightening torque100 for #14–#10 AWG; 200 for #8–4/0 AWG lbf-in
Coordinated-breaker WCR at 240 VAC200,000 with a Square D type JR breaker A RMS symmetrical
External power-conductor rangeOne #14–4/0 AWG Cu/Al conductor per phase for normal and emergency/load terminals
Neutral configurationSolid neutral
Withstand and close-on rating (WCR), standard model10,000 A RMS symmetrical

Transfer & Features

Automatic/ManualAutomatic
FeaturesMountable, Water Resistant
Controller interface A/B cable#20 AWG shielded twisted pair; Belden 9402 or 8762, or equivalent
Enclosure finishANSI 49 gray
Controller interface PWR/COM wire size#12–20 AWG
Transfer switch typeStandard
Load-control connection wire size#12–18 AWG
Transfer switch configurationStandard
Humidity range5 to 95, noncondensing %
Load centerWithout load center
Generator compatibilityAll KOHLER generators with RDC2 or DC2 controllers
Main contact materialSilver alloy
Installation environmentIndoor or outdoor
Operating temperature range-20 to 70 °C
Enclosure materialAluminum
Installation locationIndoor or outdoor
Enclosure ratingNEMA 3R
Storage temperature range-40 to 85 °C

Certifications

Certifications and ListingsUL Listed

Dimensions & Weight

Height (in.)26.5
Width (in.)18.2
Weight (lb.)33