Skip to content
Mersen

Mersen Amp-Trap 2000 AJT Class J Time-Delay Fuse

0 Reviews
SKU
AJT25

The Mersen Amp-Trap 2000 AJT25 is a non-indicating, 25 A Class J time-delay ferrule fuse rated 600 VAC and 400 VDC. Its current-limiting design is specified for low peak let-through current, and it handles typical motor and transformer inrush currents.

  • 25 A Maximum Current
  • Class J Fuse
  • 600 VAC / 400 VDC Rating
  • Time-Delay Operation
  • Current-Limiting Design
  • Ferrule Terminals

The Mersen Amp-Trap 2000 AJT25 is a non-indicating, 25 A Class J time-delay ferrule fuse rated 600 VAC and 400 VDC. Its current-limiting design is specified for low peak let-through current, and it handles typical motor and transformer inrush currents.

Product Overview

The Mersen Amp-Trap 2000 AJT25 is a non-indicating, 25 A Class J time-delay ferrule fuse rated 600 VAC and 400 VDC. Its current-limiting design is specified for low peak let-through current, and it handles typical motor and transformer inrush currents.

  • 25 A Maximum Current
  • Class J Fuse
  • 600 VAC / 400 VDC Rating
  • Time-Delay Operation
  • Current-Limiting Design
  • Ferrule Terminals

Technical Specifications

Product information and specifications for the selected item.

SKU: AJT25

Product Information

BrandMersen
MPNAJT25
SKUAJT25
CategoryFuses, Fuse Blocks & Holders

Key Specs

Current - Maximum25 A
AC Voltage Rating600 V AC
Fits Fuse Class or TypeClass J

Electrical Ratings

Current - Maximum25 A
AC Voltage Rating600 V AC
Self-certified interrupting rating300 (self-certified; UL-witnessed tests) kA
DC interrupting rating100 kA
AC interrupting rating200 kA
No-damage protectionIEC Type 2 No Damage protection for main, feeder, and branch circuits
Peak let-through behaviorCurrent-limiting design for low peak let-thru current
Inrush-current handlingHandles typical motor and transformer inrush currents
Rated frequency50/60 Hz
Minimum hold time at 500% rated current10 s
Current-limiting characteristicCurrent-limiting with low peak let-through current
IEC Type 2 protectionNo-damage protection for main, feeder, and branch circuits

Fuse Type & Indication

Fits Fuse Class or TypeClass J
Visual IndicationNon-Indicating
UL listingUL 248-8 listing, File E2137
Terminal typeFerrule
Body materialFiberglass body; provides dimensional stability in harsh environments
DC listing standardUL standard 248
CSA certificationCSA C22.2 No. 248.8
UK legislation and restricted-substances statusDeclaration covers UK Electrical Equipment (Safety) Regulations 2016 and Restriction of Hazardous Substances Regulations 2012; AJT25 is listed under Exemption 6(c)
Listings and standardsUL 248-8 (File E2137); DC UL 248; CSA C22.2 No. 248.8; IEC 60269-2-1
Arc-quenching fillerHigh-grade silica filler for fast arc quenching
Hazardous-location installationSuitable for NEC Class I Division 2 hazardous locations; Mersen highly recommends a certified sealed enclosure
EU directive and RoHS statusThe declaration covers Low Voltage Directive 2014/35/EU and RoHS Directive 2011/65/EU, amended by (EU) 2015/863; AJT25 is listed under Exemption 6(c)
EU conformity standardsIEC 60269-1 Ed.4.2:2014; IEC 60269-2 Ed.4.0:2010
UK conformity standardsEN 60269-1: 2007/A1: 2009/A2: 2014; HD 60269-2: 2013
IEC standardIEC 60269-2-1

Dimensions & Weight

Height (in.)0.814
Width (in.)0.814
Length (in.)2.25
Weight (lb.)0.097

Product Documents

Your cart

0 products 0 units

Your cart is empty.

Add products as you browse, then review them here.