AJT15

The Mersen AJT15 is a 15 A Class J time-delay fuse with ferrule terminals, rated 600 V AC and 400 V DC. Its time-delay characteristics are suited to typical motor and transformer inrush currents.

  • 15 A Maximum Current
  • Class J Time-Delay Fuse
  • 600 V AC / 400 V DC
  • Ferrule Terminals
  • Motor and Transformer Inrush
  • Current-Limiting Design

Product Overview

The Mersen AJT15 is a 15 A Class J time-delay fuse with ferrule terminals, rated 600 V AC and 400 V DC. Its time-delay characteristics are suited to typical motor and transformer inrush currents.

Technical Specifications

Product information and specifications for the selected item.

SKU: AJT15

Product Information

BrandMersen
MPNAJT15
SKUAJT15
UPC / GTIN782001962470
CategoryFuses, Fuse Blocks & Holders

Key Specs

Current - Maximum15 A
AC Voltage Rating600 V AC
DC Voltage Rating400 V DC
Fits Fuse Class or TypeClass J

Electrical Ratings

Current - Maximum15 A
AC Voltage Rating600 V AC
DC Voltage Rating400 V DC
Self-certified interrupting rating300 kA
DC interrupting rating100 kA
AC interrupting rating200 kA
Current-limiting behaviorCurrent-limiting design with low peak let-through current
Operating frequency50/60 Hz
Interrupting rating200 kA AC / 100 kA DC; self-certified 300 kA interrupting rating (UL-witnessed tests)
Selectivity2-to-1 selectivity

Fuse Type & Indication

Fits Fuse Class or TypeClass J
Visual IndicationNon-Indicating
Approvals and standardsUL 248-8 (File E2137); DC-listed to UL 248; CSA C22.2 No. 248.8; IEC 60269-2-1
Arc-quenching fillerHigh-grade silica
UK declaration and exemption statusThe declaration cites the Electrical Equipment (Safety) Regulations 2016 (S.I. 2016/1101) and hazardous-substances regulations 2012 (S.I. 2012/3032); AJT15 is listed under Exemption 6(c)
Inrush handlingTime delay for motor starting and transformer inrush
EU declaration and RoHS statusThe declaration cites Low Voltage Directive 2014/35/EU and RoHS Directive 2011/65/EU (amendment (EU) 2015/863); AJT15 is listed under Exemption 6(c)
Filler materialHigh-grade silica filler for arc quenching
Protection scopeIEC Type 2 No Damage protection for main, feeder, and branch circuits, for all types of loads
Declared standardsIEC 60269-1 Ed. 4.2: 2014; IEC 60269-2 Ed. 4.0: 2010, EN 60269-1: 2007 /A1: 2009 /A2: 2014; HD 60269-2: 2013
Terminal typeFerrule
ApplicationsMotor circuits; mains; feeders; branch circuits; lighting, heating, and general loads; transformers; control panels; circuit breaker back-up; bus duct; load centers
Body materialFiberglass body, stated to provide dimensional stability in harsh environments
No-damage protectionIEC Type 2 No Damage protection for main, feeder, and branch circuits
Listings and standardsUL listed to standard 248-8 (File E2137); DC listed to UL standard 248; CSA certified to C22.2 No. 248.8; IEC 60269-2-1
Time-delay and inrush behaviorTime-delay characteristics suited to typical motor and transformer inrush currents