The Mersen Amp-Trap 2000 AJT40ID is a 40 A Class J time-delay fuse rated 600 V AC and 400 V DC. It has SmartSpot open-fuse indication and ferrule terminals, and accommodates typical motor and transformer inrush currents.

  • 40 A Current Rating
  • 600 VAC / 400 VDC Ratings
  • Class J Fuse Type
  • Time-Delay Operation
  • SmartSpot Open-Fuse Indication
  • Ferrule Terminals

The Mersen Amp-Trap 2000 AJT40ID is a 40 A Class J time-delay fuse rated 600 V AC and 400 V DC. It has SmartSpot open-fuse indication and ferrule terminals, and accommodates typical motor and transformer inrush currents.

Product Overview

The Mersen Amp-Trap 2000 AJT40ID is a 40 A Class J time-delay fuse rated 600 V AC and 400 V DC. It has SmartSpot open-fuse indication and ferrule terminals, and accommodates typical motor and transformer inrush currents.

  • 40 A Current Rating
  • 600 VAC / 400 VDC Ratings
  • Class J Fuse Type
  • Time-Delay Operation
  • SmartSpot Open-Fuse Indication
  • Ferrule Terminals

Technical Specifications

Product information and specifications for the selected item.

SKU: AJT40

Product Information

BrandMersen
MPNAJT40
SKUAJT40
CategoryFuses, Fuse Blocks & Holders

Key Specs

Current - Maximum40 A
AC Voltage Rating600 V AC
DC Voltage Rating400 V DC
Fits Fuse Class or TypeClass J

Electrical Ratings

Current - Maximum40 A
AC Voltage Rating600 V AC
DC Voltage Rating400 V DC
Interrupting rating300 (self-certified; UL-witnessed tests) kA
Rated frequency50/60 Hz
Self-certified interrupting rating300 kA
DC interrupting rating100 kA
AC interrupting rating200 kA

Fuse Type & Indication

Fits Fuse Class or TypeClass J
Visual IndicationIndicating
Inrush handlingTypical motor and transformer inrush currents
Current-limiting characteristicExtremely current limiting for low peak let-through current
Time-delay applicationFor motor starting and transformer inrush
Fuse end styleFerrule
UK legislation complianceElectrical Equipment (Safety) Regulations 2016 (S.I. 2016/1101); Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012 (S.I. 2012/3032)
UL listingUL listed to standard 248-8, File E2137
CSA certificationCSA certified to standard C22.2 No. 248.8
Damage protectionIEC Type 2 No Damage protection for main, feeder, and branch circuits
Selectivity2-to-1 selectivity to help prevent nuisance shutdowns
Current-limiting behaviorLow peak let-thru current
ApplicationsMotor circuits; mains; feeders; branch circuits; lighting, heating, and general loads; transformers; control panels; circuit breaker back-up; bus duct; load centers
Protection performanceIEC Type 2 No Damage protection for main, feeder, and branch circuits
DC listingUL 248
IEC standardIEC 60269-2-1
UK conformity standardsEN 60269-1: 2007/A1: 2009/A2: 2014; HD 60269-2: 2013

Dimensions & Weight

Height (in.)1.062
Width (in.)1.062
Length (in.)2.37
Weight (lb.)0.1669
Filler materialHigh-grade silica filler; fast arc quenching