The Mersen Amp-Trap 2000 AJT50 is a 50 A Class J time-delay fuse with ferrule terminals. Its time-delay characteristics are specified for motor starting and transformer inrush.
The Mersen Amp-Trap 2000 AJT50 is a 50 A Class J time-delay fuse with ferrule terminals. Its time-delay characteristics are specified for motor starting and transformer inrush.
The Mersen Amp-Trap 2000 AJT50 is a 50 A Class J time-delay fuse with ferrule terminals. Its time-delay characteristics are specified for motor starting and transformer inrush.
Product information and specifications for the selected item.
| Brand | Mersen |
|---|---|
| MPN | AJT50 |
| SKU | AJT50 |
| Category | Fuses, Fuse Blocks & Holders |
| Current - Maximum | 50 A |
|---|---|
| AC Voltage Rating | 700 V AC |
| DC Voltage Rating | 400 V DC |
| Fits Fuse Class or Type | Class J |
| Current - Maximum | 50 A |
|---|---|
| AC Voltage Rating | 700 V AC |
| DC Voltage Rating | 400 V DC |
| Selectivity ratio | 2-to-1 |
| Interrupting rating | 200 AC; 100 DC kA |
| DC interrupting rating | 100 kA |
| Selectivity | 2-to-1 selectivity to help prevent nuisance shutdowns |
| Listed applications | Motor circuits, mains, feeders, branch circuits, lighting/heating/general loads, transformers, control panels, circuit-breaker backup, bus duct, and load centers |
| Current-limiting behavior | Current-limiting, with low peak let-thru current |
| Self-certified interrupting rating | 300 (self-certified; UL-witnessed tests) kA |
| AC interrupting rating | 200 kA |
| Frequency | 50/60 Hz |
| Fits Fuse Class or Type | Class J |
|---|---|
| Visual Indication | Non-Indicating |
| No-damage protection | IEC Type 2 No Damage protection for main, feeder, and branch circuits |
| EU directives and standards | The declaration cites Low Voltage Directive 2014/35/EU, RoHS Directive 2011/65/EU as amended by (EU) 2015/863, and IEC 60269-1 Ed.4.2:2014 / IEC 60269-2 Ed.4.0:2010; AJT50 is listed in the Exemption 6(c) category. |
| IEC standard | IEC 60269-2-1 |
| UL/CSA/IEC listings | UL listed to standard 248-8 (File E2137); DC listed to UL standard 248; CSA certified to C22.2 No. 248.8; IEC 60269-2-1 |
| CSA certification | CSA certified to standard C22.2 No. 248.8 |
| DC listing | DC listed to UL standard 248 |
| Body material | Fiberglass |
| Time-delay application | For motor starting and transformer inrush |
| Arc-quenching filler | High-grade silica |
| UKCA regulations and standards | The UKCA declaration cites the Electrical Equipment (Safety) Regulations 2016, UK RoHS Regulations 2012, EN 60269-1:2007/A1:2009/A2:2014 and HD 60269-2:2013; AJT50 is listed in the Exemption 6(c) category. |
| Inrush-current handling | Time-delay characteristics handle typical motor and transformer inrush currents |
| Terminal type | Ferrule |
| Filler material | High-grade silica |
| Height (in.) | 1.062 |
|---|---|
| Width (in.) | 1.062 |
| Length (in.) | 2.37 |
| Weight (lb.) | 0.1669 |