586-554-2000
Mon–Fri 6:30am–5pm · Sat 8am–3pm
586-554-2000
Mon–Fri 6:30am–5pm
The MGM Transformer Company HT75A3K2-D16 is a 75 kVA three-phase dry-type transformer with a 480 V delta primary and a 240 V delta/120 V center-tap secondary. It has aluminum windings and a 60 Hz operating frequency.
The MGM Transformer Company HT75A3K2-D16 is a 75 kVA three-phase dry-type transformer with a 480 V delta primary and a 240 V delta/120 V center-tap secondary. It has aluminum windings and a 60 Hz operating frequency.
The MGM Transformer Company HT75A3K2-D16 is a 75 kVA three-phase dry-type transformer with a 480 V delta primary and a 240 V delta/120 V center-tap secondary. It has aluminum windings and a 60 Hz operating frequency.
Product information and specifications for the selected item.
| Brand | MGM Transformer Company |
|---|---|
| MPN | HT75A3K2-D16 |
| SKU | HT75A3K2-D16 |
| Category | Electrical Transformers |
| Rated Power (kVA) | 75 |
|---|---|
| Temperature Rise (C) | 150 |
| Winding Material | Aluminum |
| Rated Power (kVA) | 75 |
|---|---|
| Temperature Rise (C) | 150 |
| High-voltage tap configuration | 2A4B at 2-1/2% |
| Three-phase output terminals | Connect the three-phase output at X1, X2, and X3 |
| Operating frequency | 60 Hz |
| Frequency | 60 Hz |
| Factory-default tap setting | Tap jumpers on positions 3–5 at nominal 480 V input |
| Single-phase output connections | Single-phase output connections are X1–X4 and X2–X4; each is 5% of capacity |
| Input-voltage limit | Do not connect if utility voltage is higher than 504 V; contact MGM |
| High-voltage BIL | 10 kV |
| Low-voltage BIL | 10 kV |
| Insulation system rating | 220 °C |
| Tap-jumper alignment | Set all three coils’ tap jumpers to the same position |
| Incoming terminals | Connect utility three-phase supply to H1, H2, and H3 |
| Single-phase loading effect | Using 10% single-phase output reduces three-phase capacity by 15% |
| Primary tap settings | Tap pair 4–5: 504 V; 4–6: 492 V; 3–5: 480 V; 3–6: 468 V; 2–6: 456 V; 3–7: 444 V; 2–7: 432 V |
| Cooling class | AA |
| Maximum warranted sound level | 50 dB |
| Winding Material | Aluminum |
|---|---|
| Material | Aluminum |
| Adjustment safety | Adjustments only by a qualified electrician; disconnect power before working on the transformer |
| Coil construction and impregnation | Continuous-wound coils impregnated with nonhygroscopic, thermosetting varnish |
| Enclosure finish | Electrostatically applied polymer polyester powder coating with a baking cycle |
| Mounting configuration | Base mounted, rigid |
| Coating color | ANSI 61 |
| Enclosure ventilation | Ventilated enclosure |
| Core/coil vibration isolation | Core and coil bolted to the enclosure base and isolated by rubber vibration-absorbing mounts |
| Core grounding | Core visibly grounded to the enclosure by a flexible grounding conductor sized to applicable UL and NEC standards |
| Certifications and Listings | CSA Certified, cUL Listed, DOE, UL Listed |
|---|
| Height (in.) | 38.5 |
|---|---|
| Width (in.) | 28.5 |
| Length (in.) | 20 |
| Weight (lb.) | 574 |
Added to cart