Skip to content
Mule Lighting

Mule Lighting SVX-H Class I, Division 2 Red Exit Sign & Emergency Light Combo

0 Reviews
SKU
SVX-H-R-D-2LA

The Mule Lighting SVX-H-R-D-2LA combines a one-sided red EXIT sign with two emergency LED heads for Class I, Division 2 locations in Groups A–D. It accepts 120/277 V AC, provides at least 90 minutes of battery-backed operation, is wet-rated for uncovered outdoor use, and includes self-diagnostics.

  • Class I, Division 2 Groups A–D
  • 120/277 V AC Input
  • At Least 90-Minute Backup
  • Wet-Rated for Uncovered Outdoor Use
  • Red, One-Sided EXIT Legend
  • Two 6 V, 4 W MR16 LED Heads

The Mule Lighting SVX-H-R-D-2LA combines a one-sided red EXIT sign with two emergency LED heads for Class I, Division 2 locations in Groups A–D. It accepts 120/277 V AC, provides at least 90 minutes of battery-backed operation, is wet-rated for uncovered outdoor use, and includes self-diagnostics.

Product Overview

The Mule Lighting SVX-H-R-D-2LA combines a one-sided red EXIT sign with two emergency LED heads for Class I, Division 2 locations in Groups A–D. It accepts 120/277 V AC, provides at least 90 minutes of battery-backed operation, is wet-rated for uncovered outdoor use, and includes self-diagnostics.

  • Class I, Division 2 Groups A–D
  • 120/277 V AC Input
  • At Least 90-Minute Backup
  • Wet-Rated for Uncovered Outdoor Use
  • Red, One-Sided EXIT Legend
  • Two 6 V, 4 W MR16 LED Heads

Technical Specifications

Product information and specifications for the selected item.

SKU: SVX-H-R-D-2LA

Product Information

BrandMule Lighting
MPNSVX-H-R-D-2LA
SKUSVX-H-R-D-2LA
CategoryEmergency Lights & Exit Signs

Key Specs

One-Sided/Two-SidedOne-sided
Damp/Wet RatingWet Rated (Uncovered Outdoor)
Letter ColorRed

Sign Format

One-Sided/Two-SidedOne-sided
Letter ColorRed

Ratings & Use

Damp/Wet RatingWet Rated (Uncovered Outdoor)
NEMA enclosure ratingNEMA 3, 4, 4X, and 12
Emergency battery runtimeAt least 90 minutes
AC lead connectionsWhite = neutral; black = 120 V AC line; orange = 277 V AC line; green = ground
Evaluated standardUL 1598
Warranty3-year factory warranty; lamps excluded; battery warranty is 20% per year pro-rata
Temperature codeT6; maximum 85 °C / 185 °F
Conduit entry fittingConduit fitting rated for Class I Division 2
Automatic self-test schedule1 minute monthly; 10 minutes every 6 months; 30 minutes yearly
Emergency lamp type6 V, 4 W MR16 LED (LA)
Junction-box compatibilityJunction box must be rated for Class I Division 2
Exit-sign LED strip power consumption<5 W
Code listingsUL 924 listed for the U.S. and Canada; CS860; NFPA; Life Safety 101
Hazardous-location enclosure sealHousing and faceplate sealed to prevent vapor and gas ingress
Battery service life5–7 years
Wall mountingWall mounting uses the side ears
Battery configuration6 V, 20 W NiCad
Monitored fault typesBattery failure, battery disconnect, charger failure, and lamp failure
Division 2 groupsGroups A, B, C, and D
Manual test methodMagnetic switch; approximately 1-minute manual test
AC input voltage120/277 V AC

Finish

Frame constructionPoly-vinyl chloride (PVC) frame with built-in gasket
Housing materialAluminum
Faceplate materialVandal-proof polycarbonate
Faceplate fastenersStainless steel, tamper-resistant

Product Documents

Your cart

0 products 0 units

Your cart is empty.

Add products as you browse, then review them here.